Accelerated whole-heart 3D CSPAMM for myocardial motion quantification.
نویسندگان
چکیده
Myocardial tissue tagging using complementary spatial modulation of magnetization (CSPAMM) allows detailed assessment of myocardial motion. To capture the complex 3D cardiac motion pattern, multiple 2D tagged slices are usually acquired in different orientations. These approaches are prone to slice misregistration and associated with long acquisition times. In this work, a fast method for acquiring 3D CSPAMM data is proposed that allows measuring deformation of the whole heart in three breath-holds of 18 heartbeats duration each. Three acquisitions are sequentially performed with line tag preparation in each orthogonal direction. Measurement acceleration is achieved by applying localized tagging preparation and a hybrid multishot, segmented echo-planar imaging sequence. Five healthy volunteers and five patients with myocardial infarction were measured. Midwall contours were tracked throughout the cardiac cycle with an enhanced variant of the harmonic phase (HARP) technique. Circumferential shortening at end-systole ranged from 14.1% (base) to 20.1% (apex) in healthy subjects. Hypokinetic regions in patients corresponded well with regions exhibiting hyperenhancement after contrast injection. Time to maximum circumferential shortening varied more significantly over the left ventricle in patients than in volunteers (P<0.01). The proposed measurement scheme was well tolerated by patients and holds considerable potential to investigate cardiac mechanics in various diseases.
منابع مشابه
3D Whole Heart CSPAMM tagging in a single breath hold using k-t-PCA
Introduction Myocardial tagging techniques [1, 2] have shown great promise in assessing local wall motion abnormalities. Recent work has indicated the value of the method in stratifying patients for cardiac resynchronization therapy [3]. Three-dimensional data acquisition is a prerequisite for a comprehensive analysis of cardiac motion. The combination of reduced field-of-view and line tag prep...
متن کاملAccelerated 3D Tagging for Quantification of Left Ventricular Dyssynchrony in Patients after Myocardial Infarction
Introduction: Cardiac resynchronization therapy (CRT) has proved successful in larger patient populations as an adjunctive therapy for patients with drug-refractory heart failure and ventricular conduction delay. However, individual responsiveness to CRT is not yet highly predictable. Around 30% of patients do not appear to benefit from CRT [1]. This can either be attributed to inappropriate pa...
متن کاملOptimal z-Encoding Frequency for zHARP: In-vivo Validation and Comparison with SF-CSPAMM
Introduction: Quantitative functional cardiac imaging can be used to characterize healthy and diseased myocardial tissues. Imaging protocols that measure 3D motion of the heart can lead to more accurate characterization than 2D approaches. However, 3D protocols are often too time-consuming for clinical feasibility. zHARP is a fast imaging technique that can quantify 3D myocardial motion from a ...
متن کاملVolumetric motion quantification by 3D tissue phase mapped CMR
BACKGROUND The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM) CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the vo...
متن کاملTechnical note: Accelerated nonrigid motion‐compensated isotropic 3D coronary MR angiography
PURPOSE To develop an accelerated and nonrigid motion-compensated technique for efficient isotropic 3D whole-heart coronary magnetic resonance angiography (CMRA) with Cartesian acquisition. METHODS Highly efficient whole-heart 3D CMRA was achieved by combining image reconstruction from undersampled data using compressed sensing (CS) with a nonrigid motion compensation framework. Undersampled ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 59 4 شماره
صفحات -
تاریخ انتشار 2008