Optical Scattering Measurements of Laser Induced Damage in the Intraocular Lens
نویسندگان
چکیده
This study optically determines whether the amount of light scatter due to laser-induced damage to the intraocular lens (IOL) is significant in relation to normal straylight values in the human eye. Two IOLs with laser-induced damage were extracted from two donor eyes. Each IOL had 15 pits and/or cracks. The surface area of each pit was measured using a microscope. For 6 pits per intraocular lens the point spread function (PSF) in terms of straylight was measured and the total straylight for all 15 pits was estimated. The damage in the IOLs was scored as mild/moderate. The total damaged surface areas, for a 3.5 mm pupil, in the two IOLs were 0.13% (0.0127 mm(2)) and 0.66% (0.064 mm(2)), respectively. The angular dependence of the straylight caused by the damage was similar to that of the normal PSF. The total average contribution to straylight was log(s) = -0.82 and -0.42, much less than the straylight value of the normal eye.The straylight due to normal levels of laser induced damage of the IOL is much lower than normal straylight values found clinically for the normal eye and may therefore be considered not significant.
منابع مشابه
Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملOptical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia.
PURPOSE In order to select the correct intraocular lens (IOL) for implantation, it is important to measure the eye length (biometry). The IOL Master from Zeiss-Humphry is frequently used for such measurements. Because this instrument employs an optical method, any irregularities on the corneal surface or any disturbances in corneal transparency could lead to mistakes in the measurements. The ai...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملIntraocular photodisruption with picosecond and nanosecond laser pulses: tissue effects in cornea, lens, and retina.
PURPOSE Nd:YAG laser photodisruption with nanosecond (ns) pulses in the millijoule range is an established tool for intraocular surgery. This study investigates tissue effects in cornea, lens, and retina to assess whether picosecond (ps) pulses with energies in the microjoule range can increase the surgical precision, reduce collateral damage, and allow applications requiring more localized tis...
متن کاملNonlinear Responses and Optical Limiting Behavior of Ag Nanoparticle Suspension
In this study, the nonlinear optical properties and optical limiting performance of the silver nanoparticles (AgNPs) in distilled water are investigated. The nonlinear absorption coefficient of the colloid is measured by the Z-scan technique. The optical limiting behavior of the AgNP suspension is investigated under exposure to nanosecond laser pulses at 532 nm. The results show that nonlinear ...