[Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser].

نویسندگان

  • Patricia Cruz
  • Hugo David Orozco
  • Ignacio Garutti Martinez
  • Gloria Hernández Fernández
چکیده

In recent years, laser resection of lung metastases has been established as the standard procedure worldwide. To avoid airway fire, it is necessary to collapse the surgical lung. The selective lobar bronchial blockade is a technique that allows one-lung ventilation while the operated lobe is collapsed in patients with previous pulmonary resection requiring subsequent resection or with limited pulmonary reserve. We report a clinical case about our experience of a selective lobar bronchial blockade technique with a bronchial blocker (Coopdech endobronchial blocker) that was employed successfully with a double-lumen endotracheal tube in a patient with previous contralateral pulmonary resection who was scheduled for atypical resections of pulmonary metastases by laser. We selectively blocked the right intermediate bronchus for management of hypoxemia during one-lung ventilation. This technique provided adequate ventilation and oxygenation during surgery, avoiding the need of two-lung ventilation during lung metastases resection by laser. CONCLUSION This case shows that if a properly positioned double-lumen tube was already in place and the patient does not tolerate one-lung ventilation because of hypoxemia, it would be possible to provide selective lobar blockade by placing a bronchial blocker through the lumen of the double-lumen tube, avoiding the use of continuous positive airway pressure during laser surgery. This technique does not disturb the operative field or interrupt the operative procedure during resection by laser, which would occur during two-lung ventilation or used of continuous positive airway pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An update on bronchial blockers during lung separation techniques in adults.

Techniques for one-lung ventilation (OLV) can be accomplished in two ways: The first involves the use of a double-lumen endotracheal tube (DLT). The second involves blockade of a mainstem bronchus (bronchial blockers). Bronchial blockade technology is on the rise, and in some specific clinical situations (e.g., management of the difficult airway during OLV or selective lobar blockade) it can of...

متن کامل

Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report

A bronchial blocker (BB) is preferred for lung separation in patients with difficult airways. However, BBs, unlike double-lumen tubes, must be placed in the bronchus of the lung being operated on, hence can be damaged by surgical manipulation. Intubation was unexpectedly difficult in this male patient, so a Coopdech BB was placed in the right mainstem bronchus through a single-lumen tracheoscop...

متن کامل

Clinical experience of one lung ventilation using an endobronchial blocker in a patient with permanent tracheostomy after total laryngectomy

Corresponding author: Hyun Kyoung Lim, M.D., Department of Anesthesiology and Pain Medicine, Inha University Hospital, 7-206, Sinheungdong 3-ga, Jung-gu, Incheon 400-711, Korea. Tel: 82-32-890-3968, Fax: 82-32-881-2475, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/lic...

متن کامل

The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.

BACKGROUND A novel double-lumen endotracheal tube, the Papworth BiVent tube, has been designed to allow the rapid passage of a blocker into either main bronchus, without fibreoptic endoscopic guidance. METHODS The feasibility of lung isolation and one-lung ventilation (OLV) in human cadavers is examined, along with displacement of the bronchus blocker during head and neck movement. RESULTS ...

متن کامل

The tip fracture of the Coopdech bronchial blocker during insertion in the patient with lung surgery

provided the original work is properly cited. CC Bronchial blockers are simple alternative methods of facilitating placement of devices for one-lung ventilation. The Coopdech bronchial blocker (Daiken Medical, Osaka, Japan) has been clinically introduced to perform one-lung ventilation with a single-lumen tracheal tube [1]. The distal tip of the Coopdech bronchial blocker has a pre-formed angul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2018