First-line catheter ablation of paroxysmal atrial fibrillation: outcome of radiofrequency vs. cryoballoon pulmonary vein isolation.

نویسندگان

  • Florian Straube
  • Uwe Dorwarth
  • Sonia Ammar-Busch
  • Timo Peter
  • Georg Noelker
  • Thomas Massa
  • Malte Kuniss
  • Niels Christian Ewertsen
  • Kyoung Ryul Julian Chun
  • Juergen Tebbenjohanns
  • Roland Tilz
  • Karl Heinz Kuck
  • Taoufik Ouarrak
  • Jochen Senges
  • Ellen Hoffmann
چکیده

AIMS First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. METHODS AND RESULTS The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural data and outcome were analysed. From 2011 to 2014, a total of 373/4184 (8.9%) patients with PAF naïve to AAD were identified. Pulmonary vein isolation (PVI) was performed with RF (n = 180) or CB (n = 193). In the RF group, patients were older (65 vs. 61 years, P < 0.01) compared with the CB group. The procedure time was significantly shorter and radiation exposure higher in the CB group. Major adverse events occurred in 1.6% (CB) and 3.7% (RF) of patients (P = 0.22). AF/atrial tachycardia (AT) recurrence until discharge was 4.5% (RF) and 8.5% (CB, P = 0.2). Follow-up (FU) ≥12 months was available in 99 (RF) and 107 (CB) patients. After 1.4 years of FU, freedom from AF/atrial tachycardia (AT) was 61% (RF) and 71% (CB, P = 0.11). In the RF group, more patients underwent cardioversion, and a trend for more repeat ablations was observed. Persistent phrenic nerve palsy was observed in one patient treated by CB. CONCLUSION First-line ablation for PAF is safe and effective with either RF or CB. The procedure was faster with the CB, but the radiation exposure was higher. Although there was a trend for more recurrences and complications in the RF group, a more favourable risk profile in patients undergoing CB ablation might have biased the results. CLINICALTRIALSGOV IDENTIFIER NCT01360008.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary vein stenosis after second-generation cryoballoon ablation for atrial fibrillation

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF), especially in paroxysmal 1 AF patients. In addition to a radiofrequency ablation catheter, a cryoballoon has been proven as an effective technology in PVI for AF. Recently several randomized trials have shown that cryoballoon ablation was noninferior to radiofrequency ablation with respect to ef...

متن کامل

Comparing Safety and Efficacy of Irrigated Radiofrequency Catheter Ablation Versus Combined Cryoballoon and Catheter Ablation for Persistent Atrial Fibrillation.

Background: Catheter and cryoballoon ablation are established treatments for atrial fibrillation. Frequently, substrate modification of the left atrium is performed in patients with persistent AF or evidence of left atrial adverse remodeling. We compared one year outcomes of AF ablation with substrate modification utilizing radiofrequency catheter ablation (RFA) compared to a combination of cry...

متن کامل

Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation

Catheter ablation (CA) is an accepted treatment option for symptomatic atrial fibrillation (AF). Historically, CA has been performed with a point-by-point technique, using standard focal radiofrequency catheters and 3-dimensional (3D) navigation systems, with a procedural end point of electric pulmonary vein isolation (PVI). However, this CA approach requires advanced training and operator skil...

متن کامل

Initial experience of cryoballoon catheter ablation for atrial fibrillation in Hong Kong.

OBJECTIVE. To report the initial experience in using cryoballoon catheter ablation in the treatment of atrial fibrillation in Hong Kong. DESIGN. Single-centre, prospective case series. SETTING. Regional hospital, Hong Kong. PATIENTS. Sixteen patients (mean age, 55 years; standard deviation, 14 years; 11 males) with paroxysmal (n=12) or persistent (n=4) atrial fibrillation. INTERVENTIONS. Pulmon...

متن کامل

Are Balloon Based Strategies Better Than Conventional Radiofrequency Catheter Ablation: Exploring New Frontiers In The Treatment Of Atrial Fibrillation.

Paroxysmal atrial fibrillation can be eliminated with continuous circular linear lesions around the pulmonary veins using radiofrequency ablation. Due to the technical complexity of this procedure balloon-based devices have been developed to simplify pulmonary vein isolation. Cryoballoon ablation provides excellent safety and is technically less demanding when compared to radiofrequency cathete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2016