Measuring energy expenditure after stroke: validation of a portable device.

نویسندگان

  • Sarah A Moore
  • Kate Hallsworth
  • Les J C Bluck
  • Gary A Ford
  • Lynn Rochester
  • Michael I Trenell
چکیده

BACKGROUND AND PURPOSE Current means of assessing physical activity and energy expenditure have restrictions in stroke, limiting our understanding of its role in therapeutic management. This study validates a portable multisensor array for measuring free-living total energy expenditure compared with a gold standard method (doubly labeled water) in individuals with stroke. METHODS Daily energy expenditure was measured in 9 participants with stroke (73 ± 8 years) over a 10-day period with 2 techniques: a portable multisensor array and doubly labeled water. RESULTS Bland-Altman analysis revealed a mean difference of 94 kcal/day (3.8%) in total energy expenditure measures given by the multisensor array in comparison to doubly labeled water with lower and upper limits of agreement of -276 to 463.8 kcal/day (2473 ± 468 versus 2380 ± 551, P=0.167). There was strong agreement between the multisensor array and labeled water methods of capturing total daily energy expenditure (r=0.850, P=0.004). CONCLUSIONS The multisensor array is a portable and accurate method of capturing daily energy expenditure and may assist in understanding how stroke influences free-living energy expenditure and aid in clinical management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The validation of one halitosis measuring device (Etiquette checker)‎

BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...

متن کامل

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

Sports Med 2003; 33 (9): 683-698

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683 1. Historical Overview of the Measurement of Energy Expenditure (EE) Techniques . . . . . . . . . . . . . . . . 684 2. Methods for the Measurement of EE: Overview and Considerations . . . . . . . . . . . . . . . . . . . . . . ....

متن کامل

Evaluation of a portable device to measure daily energy expenditure in free-living adults.

BACKGROUND Increasing daily energy expenditure (EE) plays an important role in the prevention or treatment of several lifestyle-related diseases; however, its measurement remains problematic. OBJECTIVE The objective was to evaluate a portable armband device for measuring daily and physical activity EE compared with doubly labeled water (DLW) in free-living individuals. DESIGN Daily EE and p...

متن کامل

SenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking

The purpose of this study was to test the validity of the SenseWear Pro Armband (SWA) for the measurement of energy expenditure (EE) and step count against a criterion in persons with stroke. Twelve participants with chronic stroke (mean age 64.2 ± 10.4 years; mean gait speed 0.67 ± 0.25 m/sec) completed two trials of a six-minute walk test, while wearing a SenseWear Armband (SWA) on each arm a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2012