Bioimpedance Identifies Body Fluid Loss after Exercise in the Heat: A Pilot Study with Body Cooling

نویسندگان

  • Hannes Gatterer
  • Kai Schenk
  • Lisa Laninschegg
  • Philipp Schlemmer
  • Henry Lukaski
  • Martin Burtscher
  • Francesco Cappello
چکیده

PURPOSE Assessment of post-exercise changes in hydration with bioimpedance (BI) is complicated by physiological adaptations that affect resistance (R) and reactance (Xc) values. This study investigated exercise-induced changes in R and Xc, independently and in bioelectrical impedance vector analysis, when factors such as increased skin temperature and blood flow and surface electrolyte accumulation are eliminated with a cold shower. METHODS Healthy males (n = 14, 24.1±1.7 yr; height (H): 182.4±5.6 cm, body mass: 72.3±6.3 kg) exercised for 1 hr at a self-rated intensity (15 BORG) in an environmental chamber (33°C and 50% relative humidity), then had a cold shower (15 min). Before the run BI, body mass, hematocrit and Posm were measured. After the shower body mass was measured; BI measurements were performed continuously every 20 minutes until R reached a stable level, then hematocrit and Posm were measured again. RESULTS Compared to pre-trial measurements body mass decreased after the run and Posm, Hct, R/H and Xc/H increased (p<0.05) with a corresponding lengthening of the impedance vector along the major axis of the tolerance ellipse (p<0.001). Changes in Posm were negatively related to changes in body mass (r = -0.564, p = 0.036) and changes in Xc/H (r = -0.577, p = 0.041). CONCLUSIONS Present findings showed that after a bout of exercise-induced dehydration followed by cold shower the impedance vector lengthened that indicates fluid loss. Additionally, BI values might be useful to evaluate fluid shifts between compartments as lower intracellular fluid loss (changed Xc/R) indicated greater Posm increase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Cold Water or Ice Slurry Ingestion During Exercise Elicit a Net Body Cooling Effect in the Heat?

Cold water or ice slurry ingestion during exercise seems to be an effective and practical means to improve endurance exercise performance in the heat. However, transient reductions in sweating appear to decrease the potential for evaporative heat loss from the skin by a magnitude that at least negates the additional internal heat loss as a cold ingested fluid warms up to equilibrate with body t...

متن کامل

Constructal design of tree-shaped conductive pathways for cooling a heat generating volume

Constructal design is used to study heat removal from a square heated body with a tree shaped high thermal conductivity pathways embedded in the body. The objective is to minimize the defined maximum dimensionless temperature difference for the body. The thermal conductivity of the body is low, and there is a uniform heat generation on it. The volume of the body is fixed. The amount of high con...

متن کامل

Estimation of Body Fluid Volume by Bioimpedance Spectroscopy in Patients with Hyponatremia

PURPOSE Estimation of body fluid volume in hyponatremia is useful for diagnosis and therapeutic decision-making. Physical examination has been generally used to estimate body fluid volume, but it depends on the physician's abilities. Bioimpedance spectroscopy has been suggested to be a reliable method for the estimation of body fluid volume. Therefore, this study investigated whether bioimpedan...

متن کامل

Comparison of six weeks of Iranian traditional medicine with modern medicine along with combined exercise on body weight loss and serum lipid profile in obese women

Objective Obesity is one of the problems of today's world and has become a global epidemic. The aim of this study was to compare the effect of 6 weeks of traditional Iranian medicine with modern medicine along with combined exercise on weight loss and serum lipid profile in obese women. Methods In this applied study, 24 obese women with a BMI above 30 were randomly divided into two groups of 1...

متن کامل

Diagnosis of Heat Exchanger Scales in Cooling Water Systems

An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014