Double buffering technique for binocular imaging in a window
نویسندگان
چکیده
Binocular digital imaging is a rapidly developing branch of digital imaging. Any such system must have some means that allows each eye to see only the image intended for it. We describe a time-division multiplexing technique that we have developed for Silicon Graphics Inc. (SGITM) workstations. We utilize the “double buffering” hardware feature of the SGITM graphics system for binocular image rendering. Our technique allows for multiple, re-sizable, full-resolution stereoscopic and monoscopic windows to be displayed simultaneously. We describe corresponding software developed to exploit this hardware. This software contains user-controllable options for specifying the most comfortable zero-disparity plane and effective interocular separation. Several perceptual experiments indicate that most viewers perceive 3-D comfortably with this system. We also discuss speed and architecture requirements of the graphics and processor hardware to provide flickerless stereoscopic animation and video with our technique.
منابع مشابه
Energy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملThe Effect of FEW Scatter Correction Method in In-111 Imaging
Introduction: In nuclear medicine imaging, detection of the scattered photons along with the primary photons is one of the major problems that can lead to a decrease in ddiagnostic accuracy. Therefore, use of a suitable scatter correction method can help to improve of the image quality and increase of diagnostic accuracy. The aim of this study is evaluation of five energy wind...
متن کاملCompensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...
متن کامل