Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads

نویسندگان

  • Harikrishnan Jayamohan
  • Bruce K. Gale
  • Bj Minson
  • Christopher J. Lambert
  • Neil Gordon
  • Himanshu J. Sant
چکیده

In this paper, we report the ultra-sensitive indirect electrochemical detection of E. coli O157:H7 using antibody functionalized primary (magnetic) beads for capture and polyguanine (polyG) oligonucleotide functionalized secondary (polystyrene) beads as an electrochemical tag. Vacuum filtration in combination with E. coli O157:H7 specific antibody modified magnetic beads were used for extraction of E. coli O157:H7 from 100 mL samples. The magnetic bead conjugated E. coli O157:H7 cells were then attached to polyG functionalized secondary beads to form a sandwich complex (magnetic bead/E. coli secondary bead). While the use of magnetic beads for immuno-based capture is well characterized, the use of oligonucleotide functionalized secondary beads helps combine amplification and potential multiplexing into the system. The antibody functionalized secondary beads can be easily modified with a different antibody to detect other pathogens from the same sample and enable potential multiplexing. The polyGs on the secondary beads enable signal amplification up to 10⁸ guanine tags per secondary bead (7.5 x 10⁶ biotin-FITC per secondary bead, 20 guanines per oligonucleotide) bound to the target (E. coli). A single-stranded DNA probe functionalized reduced graphene oxide modified glassy carbon electrode was used to bind the polyGs on the secondary beads. Fluorescent imaging was performed to confirm the hybridization of the complex to the electrode surface. Differential pulse voltammetry (DPV) was used to quantify the amount of polyG involved in the hybridization event with tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) as the mediator. The amount of polyG signal can be correlated to the amount of E. coli O157:H7 in the sample. The method was able to detect concentrations of E. coli O157:H7 down to 3 CFU/100 mL, which is 67 times lower than the most sensitive technique reported in literature. The signal to noise ratio for this work was 3. We also demonstrate the use of the protocol for detection of E. coli O157:H7 seeded in waste water effluent samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Specific detection of foot-and-mouth disease serotype Asia 1 virus by carboxyl-magnetic beads conjugated with single-domain antibody

BACKGROUND Immunomagnetic nanobead (IMNB) labeled with specific antibody, has been demonstrated to be useful for the capturing and detection of viruses. RESULTS In this study, we developed an imunomagnetic bead based on carboxyl-magnetic beads (MNB) labeled with a single-domain antibody (sdAb) for capturing foot-and-mouth disease (FMD) Asia 1 virus. After magnetic separation, complexes of MNB...

متن کامل

Detection of Lawsonia intracellularis using immunomagnetic beads and ATP bioluminescence.

Lawsonia intracellularis is an obligate intracellular pathogenic bacterium that causes proliferative enteropathy in various animals. The detection of L. intracellularis in clinical and environmental samples is necessary for the diagnosis of infection and epidemiological investigations. For the detection of L. intracellularis in fecal samples, we have developed an immunological method using immu...

متن کامل

Comparison of Two Immunomagnetic Separation Methods for Detection of Mycobacterium avium subsp. Paratuberculosis in Bovine Feces

Detection of Mycobacterium paratuber culosis in feces is complicated by the slowdivision and the lipid composition of the cell wall of the bacterium. In this study, we compared a rapid and sensitive method for direct detection of M. paratuberculosis with anti-paratuberculosis chicken IgY-conjugated magnetic nanoparticles versus commercially available micro-sized paramagnetic beads. Tenfold seri...

متن کامل

Mass Barcode Signal Amplification for Multiplex Allergy Diagnosis by MALDI-MS.

A highly sensitive method based on mass-barcoded gold nanoparticles (AuNPs) and immunomagnetic separation has been developed for multiplex allergy diagnosis by MALDI mass spectrometry in a component-resolved manner. Different analytical probes were prepared by coating AuNPs with individual allergenic proteins and mass barcode, represented by polyethylene glycol molecules of various chain length...

متن کامل

Rapid and sensitive detection of aflatoxins using immunomagnetic bead-based recovery and real-time qPCR assay

Several mold species of Aspergillus produce secondary metabolites called Aflatoxins. These aflatoxins can be carcinogenic and are considered potential threats to human and animal health when ingested. Aflatoxins occur naturally in food and feed products in microgram to milligram per gram of food or feed quantities thus detection methodology should be sensitive and specific which is not obtained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015