Multiscale motion mapping: a novel computer vision technique for quantitative, objective echocardiographic motion measurement independent of Doppler: first clinical description and validation.
نویسندگان
چکیده
BACKGROUND Objective, quantitative, segmental noninvasive/bedside measurement of cardiac motion is highly desirable in cardiovascular medicine, but current technology suffers from significant drawbacks, such as subjectivity of conventional echocardiographic reading, angle dependence of tissue Doppler measurements, radiation exposure by computer tomography, and infrastructure requirements in MRI. We hypothesized that computer vision technology could represent a powerful new paradigm for quantification in echocardiography. METHODS AND RESULTS We present multiscale motion mapping, a novel computer vision technology that is based on mathematical image processing and that exploits echocardiographic information in a fashion similar to the human visual system. It allows Doppler- and border-independent determination of motion and deformation in echocardiograms at arbitrary locations. Correctness of the measurements was documented in synthetic echocardiograms and phantom experiments. Exploratory case studies demonstrated its usefulness in a series of complex motion analyses that included abnormal septal motion and analysis of myocardial twisting. Clinical applicability was shown in a consecutive series of echocardiograms, in which good feasibility, good correlation with expert rating, and good intraobserver and interobserver concordance were documented. Separate assessment of 2D displacement and deformation at the same location was successfully applied to elucidate paradoxical septal motion, a common clinical problem. CONCLUSIONS This is the first clinical report of multiscale motion mapping, a novel approach to echocardiographic motion quantification. For the first time, full 2D echocardiographic assessment of both motion and deformation is shown to be feasible. Overcoming current limitations, this computer vision-based technique opens a new door to objective analysis of complex heart motion.
منابع مشابه
Normal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کاملEchocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs
Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...
متن کاملRobot Motion Vision Part II: Implementation
The idea of Fixation introduced a direct method for general recovery of shape and motion from images without using either feature correspondence or optical flow [1,2]. There are some parameters which have important effects on the performance of fixation method. However, the theory of fixation does not say anything about the autonomous and correct choice of those parameters. This paper presents ...
متن کاملRobot Motion Vision Pait I: Theory
A direct method called fixation is introduced for solving the general motion vision problem, arbitrary motion relative to an arbitrary environment. This method results in a linear constraint equation which explicitly expresses the rotational velocity in terms of the translational velocity. The combination of this constraint equation with the Brightness-Change Constraint Equation solves the gene...
متن کاملNormal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 110 19 شماره
صفحات -
تاریخ انتشار 2004