Images and Case Reports in Arrhythmia and Electrophysiology Right Coronary Artery Fistula as a Result of Delayed Right Atrial Perforation by a Passive Fixation Lead

نویسندگان

  • Georges Khoueiry
  • Nidal Abi Rafeh
چکیده

Delayed lead perforation (DLP) is an uncommon complication of permanent pacemaker and defibrillator implantation, especially that of the right atrium (RA).1 Lead perforation is considered delayed when it occurs 30 days after implantation. The incidence of DLP has been reported to be 0.8% and is more common in elderly individuals.1,2 With the yearly increase in implanted devices, and the advance in imaging modalities, this complication is more likely to be encountered. To our knowledge, delayed right atrial perforation involving a passive fixation lead remains extremely rare and has never been reported. We describe a case of an asymptomatic right atrial DLP resulting in a pseudoaneurysm and right coronary artery (RCA) fistula, diagnosed incidentally 53 months after the implantation of a passive atrial lead. Our patient is a 67-year-old man with a medical history of hypertension, diabetes mellitus, end-stage renal disease on hemodialysis, coronary artery bypass grafting, and ischemic cardiomyopathy. The patient had a dual-chamber implantable cardioverter-defibrillator implanted for primary prevention of sudden cardiac death. A passive fixation lead (5594 CapSureR SP Novus, Medtronic; Indianapolis, IN) was implanted in the RA appendage, and the right ventricular lead (6949 Sprint Fidelis, Medtronic) was implanted in the apical septum without difficulty. The initial atrial pacing threshold was 0.5 V at 0.4 ms and 1.5 V at 0.4 ms for the ventricular lead. The initial parameters remained unchanged at regular 4-month follow-ups for the first 2 years. At the 2-year follow-up visit, the RA pacing threshold increased to 1 V at 0.5 ms and progressed to 1.5 V at 0.5 ms 3 months later. A serial chest x-ray film did not show any change in the lead position during or after this period (Figure 1). Unknown to us, the patient underwent a noncontrast computed tomographic (CT) scan of the chest in the pulmonary clinic for pulmonary nodules during the same period. The scan showed an 4.5-cm mass at the level of the atrioventricular groove in the vicinity of the right atrial lead. During a regular visit 4 years after implantation, implantable cardioverter-defibrillator telemetry showed long episodes of nonsustained ventricular tachycardia. Because of this finding, the patient underwent elective coronary angiography to assess graft patency. Coronary angiography revealed total occlusions of native coronary vessels and an occluded saphenous graft to the RCA. While injecting the native RCA, an unusual filling mass was noticed. This mass was 7 4 cm, had a saclike appearance with slow clearance of the contrast, and appeared to communicate with the RCA through a fistula. The right atrial lead of the implantable cardioverterdefibrillator appeared to be in contact with the mass on cine angiography images (Figure 2). A multidetector cardiac CT scan confirmed that the lead tip was perforating the RA and protruding into the anterior margin of the mass. The mass measured 7.1 5 cm on this CT scan. Because of the interval increase in the size of the mass, the patient underwent surgery. An intraoperative transesophageal echocardiogram further defined the mass (Figure 3). On surgical exploration, the mass was confirmed to be a right atrial perforation, with a pseudoaneurysm secondary to lead perforation (Figure 4). The surgical procedure consisted of ligation of the RCA, evacuation of the pseudoaneurysm from the thrombus, resection of the distal right atrial lead, and closure of the right atrial perforation. The patient did well postoperatively. Figure 1. Anteroposterior and lateral views of the chest x-ray film showing stable position of the leads at 4 years after implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right coronary artery fistula as a result of delayed right atrial perforation by a passive fixation lead.

Delayed lead perforation (DLP) is an uncommon complication of permanent pacemaker and defibrillator implantation, especially that of the right atrium (RA).1 Lead perforation is considered delayed when it occurs 30 days after implantation. The incidence of DLP has been reported to be 0.8% and is more common in elderly individuals.1,2 With the yearly increase in implanted devices, and the advance...

متن کامل

Delayed Esophageal Pseudodiverticulum after Anterior Cervical Spine Fixation: Report of 2 Cases

Introduction: Although perforation of the esophagus, in the anterior cervical spine fixation, is well established, cases with delayed onset, especially cases that present pseudodiverticulum, are not common. In addition, management of the perforation in this situation is debated.  Case Report:   Delayed esophageal pseudodiverticulum was managed in two patients with a history of anterior spine fi...

متن کامل

Occlusion of a congenital right coronary–to–vena cava superior fistula induces temporary junctional bradycardia and atrial fibrillation

Introduction The finding of a congenital right coronary–to–vena cava superior (RCVCS) fistula is extremely rare. The overall prevalence of coronary artery fistulae is 0.02%–0.9%, of which the coronary-to–pulmonary artery fistula is the most common type (78%) and the coronary-to–vena cava superior fistula the least common (1.8%). Symptoms such as dizziness, palpitations, angina, reduced exercise...

متن کامل

An unusual cause of atrial fibrillation in a young active duty soldier

Coronary artery fistula (CAF) is an abnormality in which the coronary artery has an anomalous connection with a venous structure such as the coronary sinus or atrium. CAF is usually congenital, but may be acquired. The prevalence in the general population is low with many asymptomatic and discovered incidentally. When symptomatic, CAF may present with dyspnea, decreasing functional capacity, an...

متن کامل

Atrial coronary arteries in areas involved in atrial fibrillation catheter ablation.

BACKGROUND The proximity to vascular structures is a limiting factor during radiofrequency ablation. However, little or no attention has been given to the atrial arterial circulation during the development of atrial fibrillation (AF) catheter ablation techniques. METHODS AND RESULTS We examined the atrial arterial circulation in areas involved in AF ablation in 24 heart specimens by colored r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012