Systematic toxicological analysis by high-performance liquid chromatography with diode array detection (HPLC-DAD).
نویسندگان
چکیده
In recent years, photodiode array detectors (DADs) have been much improved with respect to wavelength accuracy and resolution, sensitivity, linearity and software operation. UV spectra of drugs measured with up-to-date DADs from different manufacturers are in excellent agreement, have the same quality as measured by a conventional UV spectrometer and are highly reproducible. The calculation of similarity parameters by the DAD software includes the entire range of the spectra compared and allows recognition of very small differences. It was shown in a systematic study of more than 2500 toxicologically relevant substances that UV spectra have a very high specificity with respect to substance structure. Therefore, HPLC-DAD in combination with a comprehensive database of UV spectra and retention parameters is one of the most efficient techniques used in systematic toxicological analysis (STA). Furthermore, the method is advantageous for the identification of metabolites, since in many cases they have the same or very similar UV spectra compared with their respective parent substances and their retention times on reversed-phase columns are shifted in a manner typical of the particular biotransformation reaction. Beside these general aspects, practical applications of HPLC-DAD for STA are reviewed with respect to sample preparation and chromatographic conditions. The efficiency of the method is demonstrated for an example of a routine procedure using liquid-liquid extraction with CH 2 Cl 2 and protein precipitation for sample preparation, a system of three isocratic mobile phases with different acetonitrile/phosphate buffer ratios and RP8 columns for chromatography and a database of 2682 UV spectra and relative retention times for substance identification.
منابع مشابه
Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry.
Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolac...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملExtraction, Identification and Thermal Stability of Anthocyanins from Eggplant Peel as a Natural Colorant
In the present study, various mixtures of aqueous ethanol and acetone solutions were utilized to extract anthocyanins from eggplant peel by a discontinuous process to obtain a natural red-purple colorant. First, the most appropriate combination for extraction solvent was selected as ethanol 70 wt in water acidified with acetic acid 3 wt, which was determined by analysis of extraction yields and...
متن کاملApplication of high-speed counter-current chromatography coupled with high-performance liquid chromatography-diode array detection for the preparative isolation and purification of hyperoside from Hypericum perforatum with online purity monitoring.
Following preparative isolation and purification by high-speed counter-current chromatography (HSCCC), the collected fractions were generally analyzed by high-performance liquid chromatography (HPLC) to determine the relative purities of each fraction. Our paper reports for the first time a preparative isolation-purity detection hyphenated system: online coupling of HSCCC with high-performance ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 42 11 شماره
صفحات -
تاریخ انتشار 2004