Size selective dustiness and exposure; simulated workplace comparisons.
نویسندگان
چکیده
A simulated workplace study was conducted to investigate the relation between inhalation exposure and dustiness determined with a rotating drum dustiness tester. Three powders were used in the study, i.e. magnesium stearate, representing a very dusty powder, and aluminium oxide and calcium carbonate, representing low and very low dusty powders, respectively. Two scenarios of handling small volume of powders were included; sweeping/cleaning and scooping/weighing/adding. Size-selective dust exposure was assessed using MultiDust (dual-fraction) IOM and RespiCon sampling heads. For the present operation scenarios, dustiness showed itself to be the major determinant of exposure and explained approximately 70% of the exposure variances. The ratios of respirable and inhalable fractions as determined by dustiness tests were comparable with the ratios observed for exposure. The results emphasize the relevance of dustiness as a parameter to characterize substances according to potential for exposure.
منابع مشابه
Dustiness of different high-temperature insulation wools and refractory ceramic fibres.
Recent regulations are encouraging the replacement of older types of man-made mineral fibre by more soluble and, thus, less biopersistent compositions. In order for there to be any health benefits from this policy and to gain maximum benefit from such substitutions, the use of the new materials should not increase exposure. The work reported here was undertaken to investigate the use of new hig...
متن کاملComparative Evaluation of the Dustiness of Industrial Minerals According to European Standard
A range of industrial minerals was tested using the rotating drum and the continuous drop methods, the two methods proposed by the published European standard EN 15051 [CEN. (2006) EN 15051 Workplace atmospheres—measurement of the dustiness of bulk materials— requirements and test methods. Brussels, Belgium: European Committee for Standardization], to evaluate and compare their dustiness. The a...
متن کاملDustiness of Fine and Nanoscale Powders
Dustiness may be defined as the propensity of a powder to form airborne dust by a prescribed mechanical stimulus; dustiness testing is typically intended to replicate mechanisms of dust generation encountered in workplaces. A novel dustiness testing device, developed for pharmaceutical application, was evaluated in the dustiness investigation of 27 fine and nanoscale powders. The device efficie...
متن کاملMethod to evaluate the dustiness of pharmaceutical powders.
The trend among pharmaceutical companies to develop selective drugs of high potency has pushed the industry to consider the potential of each hazardous ingredient to become airborne. Dustiness issues are not unique to the pharmaceutical industry, but are relevant to any industry where powdered materials are mixed, transferred and handled. Interest in dustiness is also driven by concerns for wor...
متن کاملCombined single-drop and rotating drum dustiness test of fine to nanosize powders using a small drum.
A dustiness test has been developed that performs both a single-drop and a continuous rotation test using a 6-g sample. Tests were completed on pigment-grade and ultrafine TiO2, two grades of corundum (Aloxite), yttrium-stabilized zirconia (Y-zirconia) granules, fumed silica, goethite, talc and bentonite. The generated particles were quantified by counting and sizing at 1-s time resolution usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 50 5 شماره
صفحات -
تاریخ انتشار 2006