Varied High-Voltage Conditions
نویسنده
چکیده
Refined Kerr electrooptical fringe-pattern methods are used to study time and space variations in the electric field between the electrodes of parallel-plate capacitors filled with liquid nitrobenzene. Photographs of fringe-pattern data recorded during application of high direct (both positive and negative) and sinusoidal voltages, ranging in frequency from 40 to 200 Hz, are compiled to enable computation of space-charge distortions of the field in bulk of the liquid during the stress of high-field (up to 85-kV/cm) operation. The measurements reveal significant differences between the field and charge behavior under short pulse (microsecond) voltage conditions, during prolonged dc operation, after sudden changes in the dc voltage level and polarity, and, for the first time, at various intervals over the course of entire cycles of sinusoidal voltage. The results show that space-charge distortion in the interelectrode field is influenced by the level, frequency, and duration of applied voltage. Discussions of effects believed due to particulate charge carriers, to electrohydrodynamic motion of the liquid, and to the electrode materials are also included.
منابع مشابه
A New Topology for Dynamic Voltage Restorer Using High Frequency Link
In this paper a new topology for Dynamic Voltage Restorer (DVR) with high frequency link is proposed. This topology is able to compensate different types of voltage disturbances such as voltage sag, voltage swell and voltage harmonics. According to the obtained equations, this topology operates as a controllable current source to charge the series capacitor. Due to using High Frequency Transfor...
متن کاملImpact of Initial Conditions and Voltage Source on the Initiation of Fundamental Frequency Ferroresonance
The impact of initial conditions on the initiation of fundamental frequency ferroresonance is investigated. The investigation is carried out by simulating the behaviour of the mathematical model of ferroresonant circuit realized in the laboratory. The initiation of fundamental frequency ferroresonance is investigated by varying the values of phase angle and amplitude of voltage source in order ...
متن کاملNumerical Simulation of HiPEP Ion Optics
The ffx code was used to investigate the lifetime and propellant throughput capability of the High Power Electric Propulsion (HiPEP) thruster ion optics as part of NASA’s Project Prometheus. Erosion predictions are presented as a function of beamlet current, accel grid voltage, and propellant utilization efficiency. These predictions were then compared to the lifetime goals of the thruster, and...
متن کاملDesign and Simulation of a New DC Power Supply Based on Dual Bridge Matrix Converter
A conventional high power DC power supply systems consist of a three-phase diode rectifier followed by a high frequency converter to supply loads at regulated DC voltage. These rectifiers draw significant harmonic currents from the utility, resulting in poor input power factor. In this paper, a DC power supply based on dual-bridge matrix converter (DBMC) with reduced number of switches is p...
متن کاملMicrostructure Investigation of 13Cr-2Mo ODS Steel Components Obtained by High Voltage Electric Discharge Compaction Technique
Refractory oxide dispersion strengthened 13Cr-2Mo steel powder was successfully consolidated to near theoretical density using high voltage electric discharge compaction. Cylindrical samples with relative density from 90% to 97% and dimensions of 10 mm in diameter and 10-15 mm in height were obtained. Consolidation conditions such as pressure and voltage were varied in some ranges to determine ...