An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography.
نویسندگان
چکیده
We are developing a Time-of-Flight Positron Emission Tomography detector using flat panel micro-channel plate photomultiplier tubes (MCP PMT). The high-speed waveform sampling data acquisition is adopted to exploit the fast time response of MCP PMT efficiently by using transmission-line readout scheme. To demonstrate the feasibility of the proposed detector, prototype detector modules were built using Photonis XP85022 MCP PMT, transmission-line board (TL), and high-speed waveform sampling electronics equipped with DRS4 chips. The MCP/TL module was coupled to single LYSO crystal, and experimental tests have been conducted in a coincidence setup to measure the responses to 511 keV annihilation photon. The details of the prototype module, experimental setup, and the preliminary results are presented and discussed.
منابع مشابه
Choosing a Suitable Framework for Flexible Simulation of a Picosecond TOF Device
In this paper, we examine the simulations of two different applications of a Picosecond time-of-flight (TOF) detector. The system uses Cherenkov light created in the window of the photomultiplier tube (PMT) as the detecting medium. We examine the possibilities of using GEANT4 [1], and of using the simulation package called Geant4 Application for Tomographic Emission (GATE) [2]. With some simple...
متن کاملStudy of Silicon Photomultipliers for Positron Emission Tomography (PET) Application
A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for PET applications. It has similar sensitivity and gain to the industry standard photomultiplier tube (PMT), but has advantages such as smaller size and insensitivity to magnetic field. These properties make this detector an active area of research in the PET field. I will study a simplified setup, comprised of...
متن کاملSingle Photon Imaging and Instrumentation
Abbreviations 2D, 3D 2-dimensional, 3-dimensional CZT cadmium zinc telluride EKG electric signal from the heart FBP filtered backprojection FOV field-of-view GE General Electric Ge(Li) germanium detector doped with lithium MLEM maximum likelihood expectation maximization NaI(Tl) sodium iodine doped with thallium NM nuclear medicine OSEM ordered subset expectation maximization PET positron emiss...
متن کاملAn overview on Ga-68 radiopharmaceuticals for positron emission tomography applications
Gallium-68 a positron emitter radionuclide, with great impact on the nuclear medicine, has been widely used in positron emission tomography (PET) diagnosis of various malignancies in humans during more recent years especially in neuroendocrine tumors (NETs). The vast number of 68Ge/68Ga related generator productions, targeting molecule design (proteins, antibody fragments,...
متن کاملNovel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.
A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics procedia
دوره 37 شماره
صفحات -
تاریخ انتشار 2012