Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study
نویسندگان
چکیده
INTRODUCTION The objective of this study was to evaluate the changes of the anterior chamber (AC) of the eye after implantable Collamer lens (ICL) implantation in high myopia by using the Pentacam. METHODS The prospective study included 34 high myopic patients (34 eyes). All patients were treated with Visian implantable Collamer lens (ICL) (Staar Surgical Co.) implantation. The Pentacam (Oculus) was used for all cases preoperatively and 1, 3 and 6 months postoperatively. AC angle (ACA), AC volume (ACV), central AC depth (CACD), ICL vault, central corneal thickness (CCT), pupil diameter (PD), K readings and intraocular pressure (IOP) were recorded. RESULTS Our study included 34 eyes of 34 patients, 20 females (59%) and 14 males (41%). Mean ACA was 36.93° ± 4.75° preoperatively, 25.17° ± 5.64° and 25.23° ± 6.05° 1 and 3 months postoperatively (p < 0.001). Mean ACV was 191.24 ± 11.18 mm3 preoperatively, 141.53 ± 16.77 and 142.11 ± 15.89 mm3 1 and 3 months postoperatively (p < 0.001). Mean CACD was 3.59 ± 0.17 mm preoperatively, 2.83 ± 0.24 mm and 2.96 ± 0.25 mm 1 and 3 months postoperatively (p < 0.001). The ICL vault decreased from 0.556 ± 0.033 mm 1 month postoperatively to 0.431 ± 0.056 mm 3 months postoperatively (p < 0.001). There were no statistically significant differences for any of the AC parameters among measurements taken 3, 6 and 12 months postoperatively. There were no statistically significant differences between preoperative and any postoperative measurements of CCT, PD and K readings. CONCLUSIONS ICL implantation for correction of high myopia leads to significant changes in the anterior chamber angle, volume and depth and insignificant changes in the pupil diameter, CCT and K readings.
منابع مشابه
Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure
Purpose. To assess intraocular pressure (IOP), lens vaulting, and anterior chamber (AC) angle width, following V4C implantable Collamer lens (ICL) procedure for myopic refractive error. Methods. A prospective case series that enrolled 54 eyes of 27 patients that were evaluated before and after V4C phakic posterior chamber Collamer lens implantation for correction of myopic refractive error. Pre...
متن کاملComparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...
متن کاملEvaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia
Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...
متن کاملPseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia.
PURPOSE To report a case of bilateral glaucoma related to pseudophacomorphic mechanism in one eye and pupillary block in the other eye after Visian Implantable Collamer Lens (ICL, STAAR Surgical) insertion. METHODS A 44 year-old female with high myopia underwent bilateral ICL implantation of MICL12.6 after sulcus diameter measurements were performed by Pentacam. RESULTS Pseudophacomorphic g...
متن کاملAcetazolamide-induced bilateral choroidal effusion following insertion of a phakic implantable collamer lens.
PURPOSE To present the case of a 28-year-old man with acetazolamide-induced bilateral choroidal effusion after uneventful surgery of the second eye in delayed sequential bilateral insertion of an implantable collamer lens for hyperopia. METHODS Case report. RESULTS Surgery of the left eye was uneventful, and the implantable collamer lens was implanted 3 weeks later in the right eye. Twenty-...
متن کامل