Lateral decubitus positioning for cervical nerve root block using CT image guidance minimizes effective radiation dose and procedural time.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Cervical steroid injections are a minimally invasive means of providing pain relief to patients with cervical radiculopathy. CT guidance offers many potential advantages. We developed a technique with the patient in the lateral position with a lateral needle trajectory to minimize the required needle depth from skin to target and a near-vertical needle trajectory. The aim of this study was to analyze the cohort for complications, procedural time, and effective radiation dose. MATERIALS AND METHODS This was a retrospective evaluation of a single-center patient cohort. PACS images from the procedures were reviewed for needle depth, procedural time, and CTDI(vol). An anatomically relevant conversion factor was used to calculate the effective dose. RESULTS One hundred sixteen cases from 110 patients were identified. The average patient age was 55 years. There were no complications. In 50% of cases, C5-6 was targeted. The average time was 6 minutes, and the average effective radiation dose, 0.51 mSv (0.21-2.56 mSv). Needle-insertion length from the skin to the target was highly correlated with a need for >3 needle repositioning adjustments and scan series (ρ = 0.52, P < .001) and increased procedural time (ρ = 0.42, P < .001). The angle of needle insertion relative to the floor was significantly correlated with an increased number of needle adjustments for depths >25 mm and a longer procedural time (ρ = 0.29, P = .01) but not for depths <25 mm. CONCLUSIONS The lateral patient position with CT guidance is safe and allows use of a short needle in a vertical trajectory. This reduces the number of needle adjustments and imaging series to provide a short procedural time with a low effective radiation dose from the procedure.
منابع مشابه
Laser-Guided Cervical Selective Nerve Root Block with the Dyna-CT: Initial Experience of Three-Dimensional Puncture Planning with an Ex-Vivo Model
BACKGROUND Cervical selective nerve root block (CSNRB) is a well-established, minimally invasive procedure to treat radicular cervical pain. However, the procedure is technically challenging and might lead to major complications. The objective of this study was to evaluate the feasibility of a three-dimensional puncture planning and two-dimensional laser-guidance system for CSNRB in an ex-vivo ...
متن کاملLower cervical nerve root block using CT fluoroscopy in patients with large body habitus: another benefit of the swimmer's position.
We describe a method of performing lower cervical nerve root block (CNRB) with CT fluoroscopy in patients with large body habitus using the swimmer's position. This approach reduces image noise with acceptable visualization of vital structures and improved foraminal/root access. Anticipated use of the swimmer's position coupled with minimally modified radiation exposure parameters can limit rad...
متن کاملImage Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques
Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...
متن کاملRadiation Dose and Procedure Time for 994 CT-guided Spine Pain Control Procedures.
BACKGROUND Image guidance for spine pain control procedures, including epidural steroid injection, nerve root block, and facet block, can be performed with either computed tomography (CT) or conventional fluoroscopy. CT has the advantage of improved anatomic localization and use of air for contrast; however, there are concerns that CT leads to higher radiation dose and longer procedure time. ...
متن کاملSelective lumbar nerve root blocks with CT fluoroscopic guidance: technique, results, procedure time, and radiation dose.
CT fluoroscopy may be used as a rapid and effective means of guiding needle placement when performing selective lumbar nerve root blocks. In this set of patients, the average external radiation dose was 0.73 mrem per procedure, with an average of 2 seconds of CT-fluoroscopy time and four images per procedure. Average physician room time was 7 minutes. Use of intermittent CT fluoroscopy during l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2013