End-diastolic fractional flow reserve: comparison with conventional full-cardiac cycle fractional flow reserve.

نویسندگان

  • David A Chalyan
  • Zhang Zhang
  • Shigeho Takarada
  • Sabee Molloi
چکیده

BACKGROUND Diastolic fractional flow reserve (dFFR) has been shown to be highly sensitive for detection of inducible myocardial ischemia. However, its reliance on measurement of left-ventricular pressure for zero-flow pressure correction, as well as manual extraction of the diastolic interval, has been its major limitation. Given previous reports of minimal zero-flow pressure at end-diastole, we compared instantaneous ECG-gated end-diastolic FFR with conventional full-cardiac cycle FFR and other diastolic indices in the porcine model. METHODS AND RESULTS Measurements of FFR in the left anterior descending and left circumflex arteries were performed in an open-chest swine model with an external occluder device on the coronary artery used to produce varying degrees of epicardial stenosis. An ultrasound flow-probe that was placed proximal to the occluder measured absolute blood flow in ml/min, and it was used as a gold standard for FFR measurement. A total of 17 measurements at maximal hyperemia were acquired in 5 animals. Correlation coefficient between conventional mean hyperemic FFR with pressure-wire and directly measured FFR with flow-probe was 0.876 (standard error estimate=0.069; P<0.0001). The hyperemic end-diastolic FFR with pressure-wire correlated better with FFR measured directly with flow-probe (r=0.941, standard error estimate=0.050; P<0.0001). CONCLUSIONS Instantaneous hyperemic ECG-gated FFR acquired at end-diastole, as compared with conventional full-cardiac cycle FFR, has an improved correlation with FFR measured directly with ultrasound flow-probe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic fractional flow reserve to assess the functional severity of moderate coronary artery stenoses: comparison with fractional flow reserve and coronary flow velocity reserve.

BACKGROUND Coronary blood flow occurs mainly during the diastolic phase of each cardiac cycle and is mainly dependent on diastolic driving pressure, especially in the left anterior descending coronary artery (LAD). We hypothesized that calculation of the ratio of the diastolic driving pressure of a stenotic LAD to its normal value, namely diastolic FFR (d-FFR), might provide precise insight int...

متن کامل

Comparative analysis of the effects of monetary and government financial expenditures shocks in the context of fractional and full reserve banking in Iran: DSGE approach

The present study aims to investigate the effects of monetary and financial shocks on macroeconomic variables in fractional and full reserve banking conditions. To this end, two stochastic dynamic general equilibrium models have been designed in terms of the realities of Iran's economy and then the effects of shocks have been studied. After determining the input values ​​of the model and estima...

متن کامل

Repair of all the components of the syndrome of aortic regurgitation and VSD.

Heyndrickx GR. Intracoronary and intravenous adenosine 50-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 2003;107:1877–1883. 21. Pijls N, van Son J, Kirkeeide R, De Bruyne B, Gould K. Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenos...

متن کامل

Fractional Flow Reserve and Coronary Computed Tomographic Angiography

Background: Invasive Fractional Flow Reserve Obstructive coronary artery disease (CAD) produces symptoms and increases the risk of adverse cardiac outcomes. However, determining whether a particular coronary stenosis is responsible for causing myocardial ischemia can be challenging, even with invasive coronary angiography (ICA). To help guide decisions in the cardiac catheterization laboratory,...

متن کامل

Blood oxygen level dependent and adenosine-perfusion imaging correlates to invasive measurement of fractional flow reserve

Background It has been shown that blood oxygen level dependent (BOLD) cardiac magnetic resonance imaging (CMR) is able to detect myocardial perfusion differences. However, validation of BOLD CMR against myocardial perfusion reserve (MPR) and fractional flow reserve (FFR) is lacking. We sought to analyze the potential diagnostic accuracy of BOLD CMR in comparison to invasively measured FFR which...

متن کامل

ذخیره در منابع من