Laser vs. suture nerve anastomosis.

نویسندگان

  • T C Huang
  • R H Blanks
  • M W Berns
  • R L Crumley
چکیده

The repair of injured or transected nerves is frequently encountered in head and neck surgery. Recently, CO2 lasers with milliwatt capability and micrometer spot sizes have been developed that may be used in nerve anastomosis. A comparative study was performed between microsuture and CO2 laser repair of transected sciatic nerves in rats. Nerve regeneration was measured in terms of morphology, electrophysiology, and function. Histologic studies revealed no difference in the size and number of regenerated axons, although there was less scar tissue formation at the anastomotic site with the laser repair. EMG and nerve conduction velocity were similar for the two repair methods. Functional recovery, as determined objectively using measurements of gait footprints, showed no difference between suture and laser repair. Laser-repaired nerves did have a higher dehiscence rate, although this problem can probably be prevented by splinting the rats postoperatively. However, laser repair was faster and simpler than suture repair and required less manipulation of the nerve. This study shows laser repair of peripheral nerves is possible with results comparable to conventional microsuture neurorrhaphy. Laser nerve anastomosis may be an effective alternative to suture nerve repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LASER - ASSISTED MICROSURGICAL ANASTOMOSIS OF CAROTID ARTERY IN THE RAT USING Nd-YAG LASER

End-to-end anastomosis in the A.Carotis communis of rats (average diameter 0,8-1,Omm) was achieved using Nd-YAG laser, Morphological and histological findings of laser anastomosis and suture anastomosis specimens were compared by the LAMA technique, The rats were examined 1 day. 1 month and 2 months postoperatively. Macroscopic. angiographic. histological and SEM studies showed no development o...

متن کامل

The effect of different suture materials on the safety of colon anastomosis in an experimental peritonitis model.

BACKGROUND The aim of this experimental study was to compare the safety of different suture materials in a left colonic anastomosis in the presence of peritonitis. MATERIALS AND METHODS Twenty-one male Wistar albino rats were randomly divided into three groups. First, left colonic injuries were created in all groups for the peritonitis model. After 24 hours, coated polyglactin 910 and silk su...

متن کامل

Laser ureteral anastomosis using intraluminal albumin stent in a porcine model.

BACKGROUND AND OBJECTIVES We compared ureteral anastomosis using a laser and intraluminal albumin stent with both conventional suturing and laser soldering techniques. STUDY DESIGN/MATERIALS AND METHODS Twelve pigs underwent bilateral ureteral anastomoses (N = 24) using one of the three anastomotic methods: (1) laser welding with intraluminal albumin stent (N = 11); (2) with albumin solder (N...

متن کامل

Laser nerve welding

Microsurgial suture (Conventional microsurgical suture repair, CMSR) is the most commonly used method for anastomosis of severed peripheral nerves. Functional recovery after this type of repair is often inadequate, however, even though the peripheral nervous system has a remarkable ability to regenerate adequate sizes and numbers of axons. The most significant problems with microsuture repair a...

متن کامل

An investigation of the potential for laser nerve welding.

Suture repair of a severed peripheral nerve is cumbersome, presents a focus for infection and neuroma formation, and does not always produce adequate stump alignment. An alternative form of repair is laser nerve welding, which is attractive because it does not introduce foreign material into the anastomotic site, it forms a circumferential seal, and it can be performed in difficult-to-reach are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery

دوره 107 1  شماره 

صفحات  -

تاریخ انتشار 1992