Optimizing the coagulation process in a drinking water treatment plant -- comparison between traditional and statistical experimental design jar tests.

نویسندگان

  • M Zainal-Abideen
  • A Aris
  • F Yusof
  • Z Abdul-Majid
  • A Selamat
  • S I Omar
چکیده

In this study of coagulation operation, a comparison was made between the optimum jar test values for pH, coagulant and coagulant aid obtained from traditional methods (an adjusted one-factor-at-a-time (OFAT) method) and with central composite design (the standard design of response surface methodology (RSM)). Alum (coagulant) and polymer (coagulant aid) were used to treat a water source with very low pH and high aluminium concentration at Sri-Gading water treatment plant (WTP) Malaysia. The optimum conditions for these factors were chosen when the final turbidity, pH after coagulation and residual aluminium were within 0-5 NTU, 6.5-7.5 and 0-0.20 mg/l respectively. Traditional and RSM jar tests were conducted to find their respective optimum coagulation conditions. It was observed that the optimum dose for alum obtained through the traditional method was 12 mg/l, while the value for polymer was set constant at 0.020 mg/l. Through RSM optimization, the optimum dose for alum was 7 mg/l and for polymer was 0.004 mg/l. Optimum pH for the coagulation operation obtained through traditional methods and RSM was 7.6. The final turbidity, pH after coagulation and residual aluminium recorded were all within acceptable limits. The RSM method was demonstrated to be an appropriate approach for the optimization and was validated by a further test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The simultaneous removal of turbidity and humic substances from water using the enhanced coagulation process

This study aimed to investigate the efficiency of the enhanced coagulation (EC) process for the simultaneous removal of turbidity and humic substances (HS) from raw water from the Sanandaj Water Treatment Plant (SWTP). This study was conducted on a laboratory scale using a jar test device and ferric chloride (FeCL3) as the coagulant. Accordingly, the effects of pH and coagulant dosag...

متن کامل

A comparative study of prediction models for Coagulation process in drinking Water Treatment Plants

Coagulation process is an essential part of drinking water treatment operations. The jar test is a widely-used laboratory procedure to determine the quantity of coagulation chemical dosages for water treatment plants. However, the test is not effective for real-time control of this process due to the nonlinear behaviour and rapid variations of water quality parameters. In this study, empirical ...

متن کامل

Experimental investigation, modeling, and optimization of combined electro-(fenton/coagulation/flotation) process: design of experiments and artificial intelligence systems

In this study, a combined electro-(Fenton/coagulation/flotation) (EF/EC/El) process was studied via degradation of Disperse Orange 25 (DO25) organic dye as a case study. Influences of seven operational parameters on the dye removal efficiency (DR%) were measured: initial pH of the solution (pH0), applied voltage between the anode and cathode (V), initial ferrous ion concentration (CFe), initial...

متن کامل

Wastewater Treatment of Stone Cutting Industries by Coagulation Process

Background & Aims of the Study: The wastewater created as a result of stone cutting industries enters some pools for re-consumption so that its suspended solids settle by gravity. By taking to account the high volume of water and sludge, treatment of wastewater and removal of sludge cause many problems for stone cutting units. The objective of this study was to determine the quality of wast...

متن کامل

Optimization of fluoride in water using alum with response surface methodology

Introduction: Fluoride counts an essential element for human health. Therefore, both low and excessive concentrations of that element in drinking water may cause health problems for the consumers. The present study aims to optimize fluoride base in drinking water using Alum response surface methodology. Methods: The present study is an analytical research which uses surface response method b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water science and technology : a journal of the International Association on Water Pollution Research

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 2012