Clinical aspects of a 2.0-mm locking plate system for mandibular fracture surgery.

نویسندگان

  • Sebastian Sauerbier
  • Jana Kuenz
  • Silke Hauptmann
  • Christiaan Frederik Hoogendijk
  • Niels Liebehenschel
  • Ralf Schön
  • Rainer Schmelzeisen
  • Ralf Gutwald
چکیده

PURPOSE The use of a 2.0-mm locking plate system was evaluated in mandibular surgery. PATIENTS AND METHODS 53 patients (42 male, 11 female) with a total of 56 mandibular fractures were treated with a 2.0-mm mini-locking-plate system and retrospectively examined. Gender, age, cause of fracture, surgical access, classification of fractures, osteosynthesis, postsurgical findings and complications were evaluated. RESULTS Assault in male patients (mean age 31) was the most common aetiological factor. Fractures in women (mean age 43 years) mostly occurred due to falls. Mandibular angle fractures were the most common and this anatomical site also presented the highest complication rate. Only 6% of patients had minor occlusal disturbance postoperatively, and minor complications (infections and dehiscence) occurred in 14% of patients in this study. Major complications only occurred in one patient included in the study (1.9%). Risk factors for the development of complications in this series were a history of alcohol or tobacco use, mandibular angle fractures, associated facial fractures, presurgical occlusal disturbance and concomitant dental infections. Surgical access to the fracture and the interval from injury to surgery was not associated with the development of complications. CONCLUSIONS The use of a 2.0-mm locking plate system with its advantages of improved handling characteristics, increased stability, shorter surgical time and the preservation of bony perfusion is a viable alternative to conventional miniplates in the management of mandibular fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

متن کامل

Surgical treatment of the atrophic mandibular fractures by locked plates systems: our experience and a literature review.

The management of atrophic mandibular fractures in edentulous patients represents an insidious issue for the maxillofacial surgeon due to the biological and biomechanical conditions that are unfavorable for fracture fixation and bone healing. The purpose of this study was to evaluate the results of the treatment of atrophic mandibular fractures and to compare the outcomes of different plating s...

متن کامل

Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate.

Objectives Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Methods Electronic medical records from one specialty referral centre were reviewed from March 21, 2010,...

متن کامل

Is The Late Mandibular Fracture From Third Molar Extraction a Risk Towards Malpractice? Case Report with the Analysis of Ethical and Legal Aspects

OBJECTIVES The present study reports a case of late mandibular fracture due to third molar extraction and highlights the inherent clinical, ethical and legal aspects related to this surgical complication. MATERIAL AND METHODS A female patient underwent surgical procedure for the extraction of the mandibular right third molar. Two days after the surgery the patient reported pain and altered oc...

متن کامل

Development of a Titanium Plate for Mandibular Angle Fractures with a Bone Defect in the Lower Border: Finite Element Analysis and Mechanical Test

OBJECTIVES The aim of the present study was to develop a plate to treat mandibular angle fractures using the finite element method and mechanical testing. MATERIAL AND METHODS A three-dimensional model of a fractured mandible was generated using Rhinoceros 4.0 software. The models were exported to ANSYS(®), in which a static application of displacement (3 mm) was performed in the first molar ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery

دوره 38 7  شماره 

صفحات  -

تاریخ انتشار 2010