The effect of image registration on pharmacokinetic parameter extraction using 3D DCE-MRI

نویسندگان

  • A. Melbourne
  • M. Orton
  • D. Collins
  • D-M. Koh
  • M. Leach
  • D. Hawkes
  • D. Atkinson
چکیده

Introduction: Residual patient motion between images in breath-hold DCE-MRI may compromise image analysis such as the extraction of pharmacokinetic parameters. This work analyses results of the Progressive Principal Component Registration (PPCR) algorithm [1] on six 3D DCE-MRI datasets. These datasets are acquired at a temporal resolution of 12s consisting of a 6s breath-hold volume acquisition and a further 6s breathing interval. Passage of the contrast agent bolus is particularly well defined in these datasets demonstrating the bolus passage through the heart and two defined periods of hepatic enhancement. Since these images are acquired at breath-hold, motion between subsequent time-points due to breath-hold depth inconsistency remains a problem and may impact on pharmacokinetic analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Motion Correction on Pharmacokinetic Parameter Estimation

A dynamic-contrast-enhanced magnetic resonance imaging (DCE-MRI) dataset consists of many imaging frames, often acquired both before and after contrast injection. Due to the length of time spent acquiring images, patient motion is likely and image re-alignment or registration is required before further analysis such as pharmacokinetic model fitting. Non-rigid image registration procedures may b...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Local Similarity Measures for ROI-based Registration of DCE-MRI of the Breast

Dynamic contrast-enhanced MRI (DCE-MRI) of the breast is widely used for detection and quantification purposes of breast cancer. In this paper, we present an evaluation of three similarity measures for local region of interest registration of small lesions in DCE-MRI. We evaluate the different registration results using a pharmacokinetic model function and compare measured perfusion data to the...

متن کامل

An Overdetermined System of Transform Equations in Support of Robust DCE-MRI Registration With Outlier Rejection

Quantitative hepatic perfusion parameters derived by fitting dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of liver to a pharmacokinetic model are prone to errors if the dynamic images are not corrected for respiratory motion by image registration. The contrast-induced intensity variations in pre- and postcontrast phases pose challenges for the accuracy of image registration....

متن کامل

Maximizing Accuracy and Precision on Pharmacokinetic Parameter Estimates in DCE-MRI: What is the Optimal Flip Angle?

Purpose: Dynamic Contrast Enhanced (DCE) Magnetic Resonance Imaging (MRI) is a promising tool to investigate physiological tissue properties such as blood flow, blood volume, vessel permeability and leakage space. It has been applied in various clinical studies to assess cancer stage or response to therapy. However the accuracy and reproducibility of the method remains a subject for debate sinc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008