Virtual Heart Model Technical Report
نویسندگان
چکیده
Designing bug-free medical device software is difficult, especially in complex implantable devices that may be used in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators due to firmware problems between 1990 and 2000 affected over 200,000 devices, comprising 41% of the devices recalled and are increasing in frequency. There is currently no formal methodology or open experimental platform to validate and verify the correct operation of medical device software. To this effect, a realtime Virtual Heart Model (VHM) has been developed to model the electrophysiological operation of the functioning (i.e. during normal sinus rhythm) and malfunctioning (i.e. during arrhythmia) heart. We present a methodology to extract timing properties of the heart to construct a timedautomata model. The platform exposes functional and formal interfaces for validation and verification of implantable cardiac devices. We demonstrate the VHM is capable of generating clinically-relevant response to intrinsic (i.e. premature stimuli) and external (i.e. artificial pacemaker) signals for a variety of common arrhythmias. By connecting the VHM with a pacemaker model, we are able to pace and synchronize the heart during the onset of irregular heart rhythms. The VHM has also been implemented on a hardware platform for closedloop experimentation with existing and virtual medical devices. The VHM allows for exploratory electrophysiology studies for physicians to evaluate their diagnosis and determine the appropriate device therapy. This integrated functional and formal device design approach will potentially help expedite medical device certification for safer operation.
منابع مشابه
Malmquist Productivity Index Using Two-stage DEA Model in Heart Hospitals
Abstract Heart patients displays several symptoms and it is hard to point them. Data envelopment analysis (DEA) provides a comparative efficiency degree for each decision-making units (DMUs) with several inputs and outputs. Evaluating of hospitals is one of the major applications in DEA. In this study, a comparison of additive model with standard input oriented and output oriented M...
متن کاملEvaluation of medical education virtual program: P3 model
Introduction: In e-learning, people get involved in a processand create the content (product) and make it available for virtuallearners. The present study was carried out in order to evaluatethe first virtual master program in medical education at ShirazUniversity of Medical Sciences according to P3 Model.Methods: This is an evaluation research study with post singlegroup design used to determi...
متن کاملUsing Mobile Objects as Ambassadors to Minimize Latency in World-wide Distributed Systems
In distributed systems deployed on the world-wide scale, the primary determinant of performance is latency. This technical report illustrates the importance of latency minimization in such systems by analysis of realistic world-wide distributed computing examples. It then develops a technique for distributed systems interaction — employing mobile Java objects as ambassadors, acting for clients ...
متن کاملMethod of Video-Measurements of Traffic Flow Characteristics at a Road Junction
In the theory of traffic flows the main characteristics are: intensity, speed, and density. They make it possible to use hydrodynamic models. In connection with the development of modern highways and road networks, traffic flows behavior is becoming more and more complex and diverse. In particular, the B.Kerner studies have shown that the laminar solution of hydrodynamic models is poorly corre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010