Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA).
نویسندگان
چکیده
The CAIPIRINHA (Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration) concept in parallel imaging has recently been introduced, which modifies the appearance of aliasing artifacts during data acquisition in order to improve the subsequent parallel imaging reconstruction procedure. This concept has been successfully applied to simultaneous multi-slice imaging (MS CAIPIRINHA). In this work, we demonstrate that the concept of CAIPIRINHA can also be transferred to 3D imaging, where data reduction can be performed in two spatial dimensions simultaneously. In MS CAIPIRINHA, aliasing is controlled by providing individual slices with different phase cycles by means of alternating multi-band radio frequency (RF) pulses. In contrast to MS CAIPIRINHA, 2D CAIPIRINHA does not require special RF pulses. Instead, aliasing in 2D parallel imaging can be controlled by modifying the phase encoding sampling strategy. This is done by shifting sampling positions from their normal positions in the under-sampled 2D phase encoding scheme. Using this modified sampling strategy, coil sensitivity variations can be exploited more efficiently in multiple dimensions, resulting in a more robust parallel imaging reconstruction.
منابع مشابه
Controlled Aliasing In Parallel Imaging
Recently a new parallel imaging strategy, Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA), was introduced, which modifies the appearance of the aliasing artifacts during the acquisition in order to improve the following parallel imaging reconstruction procedure. This concept was successfully applied to simultaneous multi-slice imaging (MS-CAIPIRINHA) [1] and ...
متن کاملOptimizing the undersampling scheme of 2D Controlled Aliasing in Parallel Imaging Results in a Higher Acceleration (CAIPIRINHA) in Abdominal Imaging using 3D g-factor map: A phantom study
متن کامل
Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.
PURPOSE The purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). MATERIALS AND METHODS In this ins...
متن کاملControlled aliasing in 3D parallel imaging (2D CAIPIRINHA)
A new approach to improve image quality in partially parallel 3D MRI is presented. Aliasing artifacts are manipulated by modifications of the gradient tables in the 3D phase encoding direction in order to achieve improved conditions for the final image reconstruction procedure. In contrast to conventional 3D parallel imaging methods, like 2D SENSE [1], superimposed partitions with essentially i...
متن کاملA 3D GRAPPA algorithm for volumetric parallel imaging
Introduction: In volumetric parallel imaging, data reduction is carried out along two phase encoding directions, thereby exploiting sensitivity variations in two spatial dimensions and yielding improved parallel imaging reconstruction performance. In previous work, imagedomain based two-dimensional SENSE reconstruction methods have been presented for rectangular [1] and 2D CAIPIRINHA-type reduc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 55 3 شماره
صفحات -
تاریخ انتشار 2006