Comparison of videokeratoscope and autokeratometer measurements on ellipsoid surfaces and human corneas.

نویسندگان

  • S Pardhan
  • W A Douthwaite
چکیده

BACKGROUND Various studies have compared the accuracy and repeatability of autokeratometers and videokeratoscopes using calibrated convex surfaces. We investigate the agreement between the Topcon KR-3500 autokeratometer and the EyeSys videokeratoscope on human corneas and calibrated convex surfaces. METHODS Measurements were obtained from 30 convex ellipsoidal buttons and 20 right eyes of 20 young normal human subjects. Vertex radius and p-values were compared for the two instruments. RESULTS The two instruments showed excellent agreement on convex buttons. The human data showed no such relationship. For vertex radius, a good level of agreement was obtained only for surfaces whose p-values were near unity. Repeatability was also calculated and was shown to be better with the Topcon autokeratometer than with the EyeSys videokeratoscope. Editing the EyeSys data to encompass the same corneal area as that of the Topcon improved its repeatability, although it did not reach the level of the Topcon autokeratometer. CONCLUSIONS The Topcon autokeratometer and the EyeSys videokeratoscope showed reasonable agreement for surface topography on convex conicoidal plastic test buttons but not for human corneas. Alterations in the data-capture mechanisms of videokeratoscopes could improve their ability to accurately image paraboloidal surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal topography by keratometry.

AIMS To investigate the ability of a telecentric keratometer to describe the asphericity and curvature of convex ellipsoidal surfaces and human corneas. METHODS 22 conicoidal convex surfaces and 30 human corneas were examined by conventional keratometry. Additional keratometric measurements were made when the surface was tilted in the horizontal plane relative to the instrument optical axis. ...

متن کامل

Comparison of keratometry and videokeratography after penetrating keratoplasty.

BACKGROUND As new methods for corneal curvature measurement have evolved, users of videokeratscopes need to know the practical limitations of these instruments. We assessed agreement between keratometry and videokeratography in measuring highly astigmatic corneas. METHODS Two independent examiners made three keratometric and videokeratographic measurements on each of 33 corneas after penetrat...

متن کامل

Solvation Force in Hard Ellipsoid Molecular Liquids with Rod-Sphere and Rod- Surface Interactions

In previous work, one of us calculated the Solvation force of hard ellipsoid fluid with hard Gaussian overlap potential using hard needle wall interaction and non-linear equation proposed by Grimson- Rickyazen. In present work, using density functional theory and extended restricted orientation model, the solvation force of hard ellipsoid fluid in presence of more realistic rod- sphere and rod-...

متن کامل

Accuracy of Topcon CM-1000 videokeratoscope on spherical test surfaces.

BACKGROUND Many videokeratoscopes use mathematical formulas to calculate corneal radii; calculations depend on slope, curvature, coordinate position, or focal properties of the surface. Accuracy of each type of videokeratoscope must be evaluated. A controversy exists about whether axial or tangential methods best provide a precise description of corneal shape; therefore results with the Topcon ...

متن کامل

Reproducibility of corneal astigmatism measurements with a hand held keratometer in preschool children.

AIMS To evaluate the overall accuracy and reproducibility of the Alcon portable autokeratometer (PAK) measurements in infants and young children. METHODS The accuracy of the Alcon PAK in measuring toric reference surfaces (1, 3, 5, and 7 D) under various suboptimal measurement conditions was assessed, and the reproducibility of PAK measurements of corneal astigmatism in newborn infants (n = 5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1998