Modeling and Implementation of Tcr and Vsi Based Facts Controllers

نویسندگان

  • S. Corsi
  • M. Pozzi
چکیده

This report concentrates on presenting transient stability and power ow models of Thyristor Controlled Reactor (TCR) and Voltage Sourced Inverter (VSI) based Flexible AC Transmission System (FACTS) Controllers. Appropriate models for voltage and angle stability studies are discussed in detail for the Static Var Compensator (SVC), the Thyristor Controlled Series Compensator (TCSC), the Static Var Compensator (STATCOM), the Static Synchronous Source Series Compensator (SSSC), and the Uni ed Power Flow Controller (UPFC). Finally, the implementation of the STACOMmodel into steady sate and transient stability programs is discussed through the results obtained from stability studies of a simple test system that includes a STATCOM controller. Chapter

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UPFC Siting and Sizing in Power Network Using Two Different Evolutionary Algorithm

In emerging electric power systems, increased transactions often lead to the situations where the system no longer remains in secure operating region. The flexible Ac transmission system (FACTS) controllers can play an important role in the power system security enhancement. However, due to high capital investment, it is necessary to locate these controllers optimally in the power system. FACTS...

متن کامل

Reactive power and imbalance compensation using STATCOM with dissipativity-based control

The paper investigates the use of dissipativity-based control for voltage-sourced inverters (VSI) utilized as reactive power and unbalance compensators, e.g., Static synchronous compensator (STATCOM). The approach relies on a frequency domain modeling of system dynamics using positive sequence and negative sequence dynamic components. Following the passivity-based procedure, a family of control...

متن کامل

The Optimal Design of the VSI T^2 Control Chart

Recent studies have shown that the variable sampling interval (VSI) scheme helps practitioners detect process shifts more quickly than the classical scheme (FRS). In this paper, the economically and statistically optimal design of the VSI T2 control chart for monitoring the process mean vector is investigated. The cost model proposed by Lorenzen and Vance (1986) is minimized through a genetic a...

متن کامل

Delay-Scheduled Controllers for Inter-Area Oscillations Considering Time Delays

Unlike the existing views that was introduced the existence of delay caused by the transmission of wide area measurement system data (WAMS) into the controllers input of the power oscilation damping (POD) by communication networks as a reason for poor performance of the POD controllers. This paper shows that the presence of time delay in the feedback loop may improve the performance of a POD co...

متن کامل

Design and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller

In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -