Validity, Sensitivity, Reproducibility, and Robustness of the PowerTap, Stages, and Garmin Vector Power Meters in Comparison With the SRM Device.

نویسندگان

  • Anthony Bouillod
  • Julien Pinot
  • Georges Soto-Romero
  • William Bertucci
  • Frederic Grappe
چکیده

A large number of power meters have been produced on the market for nearly 20 y according to user requirements. PURPOSE To determine the validity, sensitivity, reproducibility, and robustness of the PowerTap (PWT), Stages (STG), and Garmin Vector (VCT) power meters in comparison with the SRM device. METHODS A national-level male competitive cyclist completed 3 laboratory cycling tests: a submaximal incremental test, a submaximal 30-min continuous test, and a sprint test. Two additional tests were performed, the first on vibration exposures in the laboratory and the second in the field. RESULTS The VCT provided a significantly lower 5-s power output (PO) during the sprint test with a low gear ratio than the SRM did (-36.9%). The STG PO was significantly lower than the SRM PO in the heavy-exercise-intensity zone (zone 2, -5.1%) and the low part of the severe-intensity zone (zone 3, -4.9%). The VCT PO was significantly lower than the SRM PO only in zone 2 (-4.5%). The STG PO was significantly lower in standing position than in the seated position (-4.4%). The reproducibility of the PWT, STG, and VCT was similar to that of the SRM system. The STG and VCT PO were significantly decreased from a vibration frequency of 48 Hz and 52 Hz, respectively. CONCLUSIONS The PWT, STG, and VCT systems appear to be reproducible, but the validity, sensitivity, and robustness of the STG and VCT systems should be treated with some caution according to the conditions of measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity, Sensitivity and Reproducibility of Stages and Garmin Vector Power Meters When Compared with Srm Device

The measurement of power output (PO) during cycling has led some manufacturers to develop mobile power meters. However, such devices have to provide a valid, sensitive and reproducible PO. This study aimed to determine the validity, sensitivity and reproducibility of the Stages and Garmin Vector during both laboratory and field cycling tests. The results demonstrate that the Stages and the Garm...

متن کامل

Validity and reproducibility of the Powertap P1 power meter when compared with SRM device

Purpose: The use of power meters allows the assessment of cycling performance according to the record power profile [1]. Some power meters allow the measurement of power output (PO) in the pedals such as Look Keo Power (Look, Cedex, France) [2] and Garmin Vector (Olathe, USA) [3]. However, the results about these two systems [2, 3] should be treated with some caution given the presence of mean ...

متن کامل

Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.

PURPOSE The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). METHODS The validity of the EP was tested in the laboratory during 8 submaximal...

متن کامل

Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.

The SRM power measuring crank system is nowadays a popular device for cycling power output (PO) measurements in the field and in laboratories. The PowerTap (CycleOps, Madison, USA) is a more recent and less well-known device that allows mobile PO measurements of cycling via the rear wheel hub. The aim of this study is to test the validity and reliability of the PowerTap by comparing it with the...

متن کامل

Comparison of Binomial and Power Equations in Radial Non-Darcy Flows in Coarse Porous Media

Analysis of non-laminar flows in coarse alluvial beds has a wide range of applications in various civil engineering, oil and gas, and geology problems. Darcy equation is not valid to analyze transient and turbulent flows, so non-linear equations should be applied. Non-linear equations are classified into power and binomial equations. Binomial equation is more accurate in a wide range of velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 12 8  شماره 

صفحات  -

تاریخ انتشار 2017