A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments.
نویسندگان
چکیده
AIM To evaluate the cyclic fatigue of Mtwo Ni-Ti rotary instruments after controlled clinical use in molar teeth. METHODOLOGY Twenty Mtwo instruments of each size were selected and divided into two groups: group A consisted of 10 new instruments (control group); group B consisted of 10 used instruments. Each instrument in group B was used to clean and shape 10 root canals of molar teeth in patients. Cyclic fatigue testing of instruments was performed in tapered artificial canals with a 5-mm radius of curvature and a 60 degrees angle of curvature. In all 140, instruments were rotated until fracture and the number of cycles to failure was recorded. Data were analysed using one-way anova, Tukey's HSD test and independent sample t-test to determine any statistical difference; the significance was determined at the 95% confidence level. RESULTS A reduction of cycles to failure between new (group A) and used (group B) instruments was apparent. A statistically significant difference (P < 0.05) was noted between instruments of groups A and B in all sizes with the exception of size 40, 0.04 taper. CONCLUSIONS Clinical use significantly reduced cyclic fatigue resistance of Mtwo rotary instruments when compared with an unused control group. However, all the instruments had minimal instrument fatigue when discarded after controlled clinical use.
منابع مشابه
Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.
AIM To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals. METHODOLOGY Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were...
متن کاملCyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators – an in vivo and in vitro study
BACKGROUND The aim of the present study was to evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments after clinical use by 1 experienced and 1 novice operator. MATERIAL/METHODS Cyclic fatigue testing of instruments was performed on tapered artificial canals with a 5 mm radius of curvature and 60° angle of curvature. Twenty Mtwo instruments for each size were selected and divid...
متن کاملComparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...
متن کاملA comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)
A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...
متن کاملEffect of Deep Cryogenic Treatment on Cyclic Fatigue of Endodontic Rotary Nickel Titanium Instruments
INTRODUCTION Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. METHODS AND MATERIALS In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 39 9 شماره
صفحات -
تاریخ انتشار 2006