BACKGROUND Recently, thoracic aortic stent grafting has emerged as an alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. However, its application has been limited to descending thoracic aortic aneurysms distal to the aortic arch. We report our initial clinical experience of endovascular branched stent graft repair for aortic arch aneurysms. METHODS AND RESULTS Endovascular grafting with Inoue branched stent grafts was attempted for 15 patients with thoracic aortic aneurysms and aortic dissections under local anesthesia (n=14) or general anesthesia (n=1). Single-branched stent grafts were used in 14 patients, and a triple-branched stent graft in one. The branched stent grafts were delivered through a 22F or a 24F sheath under fluoroscopic guidance and implanted across the aneurysmal aortic arch. In 2 patients, the single-branched stent graft did not pass through the 22F sheath used. Complete thrombosis of the aneurysm was ultimately achieved in 11 patients (73%). Of 4 persistent leaks, 1 minor leak spontaneously thrombosed and 1 major leak was successfully treated by additional straight stent graft placement. In 1 patient, the right external iliac artery ruptured during the withdrawal of the sheath and was successfully repaired by the implantation of a straight stent graft. One patient with severe stenosis of the aortic graft section was successfully managed by additional stent deployment. Peripheral microembolization to a toe occurred in 1 patient, and cerebral infarction occurred in 1 other patient. Two patients who had failed to receive endovascular stent grafts died during an average follow-up of 12.6 months, 1 of pneumonia and the other of rupture of a concomitant abdominal aortic aneurysm. CONCLUSIONS This report demonstrates the technical feasibility of endovascular branched stent graft repair for aneurysms located at the aortic arch. Careful, longer follow-up and further extensive clinical trials are awaited toward establishing this technique as a recommendable alternative to surgical treatment of thoracic aortic aneurysms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular repair of the aortic arch in pigs by improved double-branched stent grafts

INTRODUCTION This study aimed to evaluate the feasibility of total endovascular repair of the aortic arch in pigs using improved integrated double-branched stent grafts. METHODS Improved self-expandable stent grafts with a main body and two integrated branches were prepared for the repair of the aortic arch in six pigs. The feasibility of using these stent grafts was evaluated with arteriogra...

متن کامل

Total aortic arch replacement with a novel four-branched frozen elephant trunk graft: first-in-man results.

OBJECTIVES The combined disease of the aortic arch and the proximal descending aorta remains a surgical challenge. With the 'frozen elephant technique', the ascending aorta, along with the aortic arch, is replaced conventionally and an endovascular stent graft is placed into the descending aorta in the antegrade manner through the open aortic arch, thereby potentially allowing for a 'single-sta...

متن کامل

Open triple-branched stent graft placement for the surgical treatment of acute aortic arch dissection

BACKGROUND The primary experience of open triple-branched stent graft placement for acute aortic arch dissection was reported. METHODS Between January 2011 and October 2011, 13 well-selected patients (mea age, 46±8.2 years; approximate range, 30~58 years) with acute aortic arch dissection underwent open triple-branched stent graft placement for total arch reconstruction. The triple-branched s...

متن کامل

A new modular stent graft to reconstruct aortic arch.

BACKGROUND Endovascular repair by stent graft has been developed as a safe and less-invasive treatment for descending thoracic and abdominal aortic diseases. In case of involvement of the aortic arch, the challenge in endovascular repair is to maintain blood flow to the brain and upper extremities. Several studies have been done trying to repair this difficult part of the aorta with different s...

متن کامل

Surgical repair and reconstruction of aortic arch in debakey type I aortic dissection: recent advances and single-center experience in the application of branched stent graft

BACKGROUND Aortic dissection (AD) represents a clinically uncommon aortic pathology which predicts a dismal prognosis if not promptly treated. In acute Debakey type I AD (ADIAD), aortic lesion extends from aortic root to even distal abdominal aorta among which aortic arch and its three main branches still remain a great surgical challenge for repair and reconstruction. Several decades have witn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 100 19 Suppl  شماره 

صفحات  -

تاریخ انتشار 1999