Comparison of eight prosthetic aortic valves in a cadaver model.
نویسندگان
چکیده
OBJECTIVES Proper valve selection is critical to ensure appropriate valve replacement for patients, because implantation of a small valve might place the patient at risk for persistent gradients. Labeled valve size is not the same as millimeter measure of prosthetic valve diameters or the annulus into which it will fit. Studies that use the labeled valve size in lieu of actual measured diameter in millimeters to compare different valves might be misleading. Using human cadaver hearts, we sized the aortic annulus with 8 commonly used prosthetic aortic valve sizers and compared the valves using geometric orifice area. This novel method for comparing prosthetic valves allowed us to evaluate multiple valves for implantation into the same annulus. METHODS Aortic annular area was determined in 66 cadavers. Valve sizers for 8 prosthetic valves were used to determine the appropriate valve for aortic valve replacement. Regression analyses were performed to compare the relationship between geometric orifice area and aortic annular area. RESULTS Tissue valves had a larger orifice area for any annular size but were not different at small sizes. Supra-annular valves were larger than intra-annular valves for the small annulus, but this relationship was not uniform with increasing annular size. CONCLUSIONS Labeled valve size relates unpredictably to annular size and orifice area. No advantage in geometric orifice area could be demonstrated between these tissue valves at small annular sizes. Valves with the steepest slope on regression analysis might provide a larger benefit with upsizing with respect to geometric orifice area.
منابع مشابه
مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملNeurologic complications of late prosthetic valve endocarditis.
We reviewed the records of 20 patients with late prosthetic valve endocarditis who were hospitalized at the University of Iowa between 1985 and 1988. There were 14 men and six women, aged 20-80 (mean 57.9) years. The infected valves were mechanical in 11 patients (six aortic and five mitral) and bioprosthetic in the other nine. Echocardiography in 12 patients demonstrated vegetations in one. Am...
متن کاملEditorial Valve in Valve Another Milestone for Transcatheter Valve Therapy
The first mechanical heart valve prosthesis, designed by Dr Charles Hufnagel, was implanted to the descending aorta of a 30-year-old woman with severe aortic regurgitation in 1952.1 Eight years after the initial successful prosthetic valve implantation, Dr Harken sutured a prosthetic valve (Starr Edwards Valve) to the aortic annulus after removing the diseased native valve. During the ensuing y...
متن کاملAnother Milestone for Transcatheter Valve Therapy
The first mechanical heart valve prosthesis, designed by Dr Charles Hufnagel, was implanted to the descending aorta of a 30-year-old woman with severe aortic regurgitation in 1952.1 Eight years after the initial successful prosthetic valve implantation, Dr Harken sutured a prosthetic valve (Starr Edwards Valve) to the aortic annulus after removing the diseased native valve. During the ensuing y...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 134 6 شماره
صفحات -
تاریخ انتشار 2007