Magnetic resonance imaging of perfusion-diffusion mismatch in rodent and non-human primate stroke models.

نویسنده

  • Timothy Q Duong
چکیده

Stroke is a leading cause of death and long-term disability. Non-invasive magnetic resonance imaging (MRI) has been widely used for the early detection of ischemic stroke and the longitudinal monitoring of novel treatment strategies. Recent advances in MRI techniques have enabled improved sensitivity and specificity to detecting ischemic brain injury and monitoring functional recovery. This review describes recent progresses in the development and application of multimodal MRI and image analysis techniques to study experimental stroke in rats and non-human primates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Granulocyte-colony stimulating factor delays PWI/DWI mismatch evolution and reduces final infarct volume in permanent-suture and embolic focal cerebral ischemia models in the rat.

BACKGROUND AND PURPOSE Granulocyte-colony stimulating factor (G-CSF) is used clinically to attenuate neutropenia after chemotherapy. G-CSF acts as a growth factor in the central nervous system, counteracts apoptosis, and is neuroprotective in rodent transient ischemia models. METHODS We assessed the effect of G-CSF on ischemic lesion evolution in a rat permanent-suture occlusion model with di...

متن کامل

MRI of Perfusion-Diffusion Mismatch in Non-Human Primate (Baboon) Stroke: A Preliminary Report

The goal of this study was to develop a clinically relevant non-human primate (baboon) stroke model and multi-parametric MRI protocols on a clinical scanner with long-term goals to better model human stroke and facilitate clinical translations of novel therapeutic strategies. Baboons were chosen because of their relatively large brain volume and that they are evolutionarily close to humans. Mid...

متن کامل

Total mismatch: negative diffusion-weighted imaging but extensive perfusion defect in acute stroke.

BACKGROUND AND PURPOSE The perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch may identify patients who benefit from thrombolysis. However, some patients exhibit a "total mismatch," ie, negative DWI but extensive PWI defect. We aimed to assess clinical and MRI data of these patients. METHODS From June 2007 to December 2008, patients with anterior circulation ischemic s...

متن کامل

Perfusion-diffusion Mismatch Predicts Early Neurological Deterioration in Anterior Circulation Infarction without Thrombolysis

Perfusion-diffusion mismatch in magnetic resonance imaging (MRI) represents the non-core hypoperfused area in acute ischemic stroke. The mismatch has been used to predict clinical response after thrombolysis in acute ischemic stroke, but its role for predicting early neurological deterioration (END) in acute ischemic stroke without thrombolysis has not been clarified yet. In this study, we pros...

متن کامل

Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.

BACKGROUND AND PURPOSE Perfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI). METHODS Acute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurological research

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 2013