Effect of measurement duration on accuracy of pulse-counting

نویسنده

  • Hiromitsu Kobayashi
چکیده

In this study, the relation between the measurement duration and accuracy of pulse-counting was quantitatively examined with special reference to low-frequency fluctuations in heart rate variability. The interbeat intervals of 70 healthy male subjects were measured in standing, sitting and supine positions. Pulse rates for various durations were calculated by objective-scoring simulation based on the heartbeat recordings of the subjects. The duration of pulse-counting continuously varied from 6 to 60 s in the simulation. Simulated pulse rates were compared with the rate calculated from the 60 s that includes the given duration, and the absolute difference between the two rates was defined as the error. Average errors of pulse-counting for 15 s were 1.89, 1.89 and 1.80 bpm for standing, sitting and supine positions, respectively. No difference in error was observed between standing and sitting positions; however, smaller errors were observed in the supine position.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses

Background Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MaterialsAndMethods In this prospective study, the depths of six kinds of sperm counting chamber...

متن کامل

A Monte Carlo Code for Simulation of Pulse Pile-up Spectral Distortion in Pulse-height Measurement

The Monte Carlo simulation code CEARPPU has been improved to obtain better accuracy for predicting pulse-height spectra measured at high counting rates. Experimental verification was carried out by measuring an Fe-55 spectrum with a Si(Li) X-ray spectrometer. Based on the spectrum measured at low counting rate, which is considered to be the “true” spectrum with no pulse pile-up distortion, the ...

متن کامل

The effect of parameters of low-frequency electrical stimulation on piriform-cortex kindled seizures in rat

Introduction: Electrical low-frequency stimulation (LFS) has antiepileptic effect, but the role of different stimulation parameters on this effect has not been determined. In this study the effect of different LFS parameters (intensity, pulse duration and train duration) on piriform-cortex kindled seizures was investigated. Methods: Seizure was produced in animals using kindling model of ep...

متن کامل

A Quantitative Study of the Effect of Electroporation on the Electropermeability and Cell Survival

Introduction: Electroporation is a practical technique used to transport the molecules across the cell membrane. The utilization of fluorescent molecules is the method widely used to evaluate the electropermeability of cell membrane as a result of pulse application. It is also possible to use mathematical methods to predict the changes caused in cell electropermeability as a result of the chang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2013