Association of mood disturbance and arrhythmia events in patients after cardioverter defibrillator implantation.

نویسندگان

  • S B Dunbar
  • L P Kimble
  • L S Jenkins
  • M Hawthorne
  • W Dudley
  • M Slemmons
  • J J Langberg
چکیده

BACKGROUND Life stresses and negative emotions, such as anxiety and depression, are associated with adverse cardiac events, including arrhythmia. Patients undergoing implantation of an automatic internal cardioverter defibrillator provide a unique opportunity to characterize these relationships since all tachyarrhythmia episodes are recorded by the device. OBJECTIVES The purpose of this study was to examine the association of emotional status after internal cardioverter defibrillator (ICD) implantation and subsequent arrhythmia events. METHODS An analysis of data obtained in a prospective longitudinal study of responses to the ICD measured mood disturbance (Profile of Mood States; POMS) before implant and at 1, 3, 6, and 9 months postoperatively. Subjects included 144 men and 32 women with a mean age of 60 +/- 13 years and a mean left ventricular ejection fraction (LVEF) of 33 +/- 12%. Arrhythmia events were measured by self-report of shocks and by ICD device interrogation to obtain the number and type (defibrillation, cardioversion, and antitachycardia pacing) of therapies delivered by the ICD. For each time point, POMS scores of subjects who had arrhythmia events were compared with those who did not. For subjects who had ICD shocks, pre-event and post-event POMS scores were also compared. Multiple logistic regression was used at each time point to determine if clinical, demographic and psychological data could predict arrhythmia events. RESULTS Patients with arrhythmia events had higher POMS scores throughout the 9 months of follow-up. Higher level of mood disturbance (specifically anxiety, fatigue, and confusion) at 1 and 3 months were independent predictors of subsequent arrhythmia events at 3 and 6 months after controlling for LVEF, the presence of coronary artery disease, pre-implant arrhythmia history, and the use of amiodarone and beta-blocking agents. There were no differences in POMS scores before and after ICD shocks, reinforcing the notion that negative emotions were a cause, rather than a consequence, of arrhythmia events. CONCLUSIONS Mood disturbances, such as anxiety, may increase the risk for arrhythmia events after ICD insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Arrhythmia/Electrophysiology Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation

Background—Patients undergoing implantable cardioverter-defibrillator (ICD) implantation are at risk of postprocedural complications. However, we do not have a risk stratification schema to identify patients at high and low risk of adverse events. Methods and Results—We analyzed data from 268 701 ICD implants submitted to the ICD Registry and developed logistic regression models to identify var...

متن کامل

Success of Device-Based Methods for Atrial Tachyarrhythmia Induction during Implantation of an Implantable Cardioverter Defibrillator with Atrial Therapy

In addition to standard ventricular therapy, cardioversion using an implantable cardioverter defibrillator (ICD) with atrial therapy is one of the many new options available for treating atrial tachyarrhythmias. New data suggest that shock efficacy for AF depends on identifying atrial defibrillation thresholds (DFT) and programming the first atrial shock to at least two times the atrial DFT [1]...

متن کامل

Antithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR)®

BACKGROUND Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. METHODS AND RESULTS Using data from National Cardiovascular Data Registry(®) Implantable Cardioverter Defibrillator Registry(™) linked with Medicare claims data, we identified 25 180 patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Depression and anxiety

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 1999