Diagnostic accuracy of the Xpert® MTB/RIF cycle threshold level to predict smear positivity: a meta-analysis.
نویسندگان
چکیده
SETTING Xpert® MTB/RIF is the most widely used molecular assay for rapid diagnosis of tuberculosis (TB). The number of polymerase chain reaction cycles after which detectable product is generated (cycle threshold value, CT) correlates with the bacillary burden.OBJECTIVE To investigate the association between Xpert CT values and smear status through a systematic review and individual-level data meta-analysis. DESIGN Studies on the association between CT values and smear status were included in a descriptive systematic review. Authors of studies including smear, culture and Xpert results were asked for individual-level data, and receiver operating characteristic curves were calculated. RESULTS Of 918 citations, 10 were included in the descriptive systematic review. Fifteen data sets from studies potentially relevant for individual-level data meta-analysis provided individual-level data (7511 samples from 4447 patients); 1212 patients had positive Xpert results for at least one respiratory sample (1859 samples overall). ROC analysis revealed an area under the curve (AUC) of 0.85 (95%CI 0.82-0.87). Cut-off CT values of 27.7 and 31.8 yielded sensitivities of 85% (95%CI 83-87) and 95% (95%CI 94-96) and specificities of 67% (95%CI 66-77) and 35% (95%CI 30-41) for smear-positive samples. CONCLUSION Xpert CT values and smear status were strongly associated. However, diagnostic accuracy at set cut-off CT values of 27.7 or 31.8 would not replace smear microscopy. How CT values compare with smear microscopy in predicting infectiousness remains to be seen.
منابع مشابه
Diagnostic accuracy of Xpert MTB/RIF for tuberculosis detection in different regions with different endemic burden: A systematic review and meta-analysis
PURPOSE To estimate the diagnostic accuracy of Xpert MTB/RIF, a systematic review and meta-analysis were carried out. METHODS Up to June 20, 2015, multiple databases were screened for relevant studies. RESULTS Accordingly, 106 studies included 52,410 samples were selected. Diagnostic accuracy of Xpert MTB/RIF for TB detection was validated against either culture or a composite reference sta...
متن کاملRapid and effective diagnosis of tuberculosis and rifampicin resistance with Xpert MTB/RIF assay: a meta-analysis.
OBJECTIVES Xpert MTB/RIF (Cepheid) assay has been introduced for the diagnosis of tuberculosis (TB) and RIF-resistance. The meta-analysis was used to establish the overall accuracy of Xpert MTB/RIF assay for diagnosing TB and RIF-resistance. METHODS Based on comprehensive searches of the Pubmed and Embase, we identified outcome data from all articles estimating diagnostic accuracy with Xpert ...
متن کاملRapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country
OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...
متن کاملThe use of an automated quantitative polymerase chain reaction (Xpert MTB/RIF) to predict the sputum smear status of tuberculosis patients.
Xpert MTB/RIF-generated cycle-threshold (C(T)) values have poor clinical utility as a rule-in test for smear positivity (cut-point ≤20.2; sensitivity 32.3%, specificity 97.1%) but moderately good rule-out value (cut-point >31.8; negative predictive value 80.0%). Thus, 20% of individuals with C(T) values >31.8 were erroneously ruled out as smear-negative. This group had a significantly lower spu...
متن کاملXpert® Mtb/Rif assay for pulmonary tuberculosis and rifampicin resistance in adults
BACKGROUND Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands-on technical time. The World Health Organization (WHO) issued initial recommendat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease
دوره 21 5 شماره
صفحات -
تاریخ انتشار 2017