Wave-front phase measurements of high-order harmonic beams by use of point-diffraction interferometry.

نویسندگان

  • D G Lee
  • J J Park
  • J H Sung
  • C H Nam
چکیده

We report the wave-front phase measurement of high-order harmonics employing point-diffraction interferometry. The high-order harmonics generated in a gas-filled hollow tube showed excellent spatial coherence over nearly the whole cross section of the harmonic beams. Using this coherent harmonic source in the extreme-ultraviolet-soft-x-ray region, we have demonstrated the operation of a point-diffraction interferometer and measured the wave-front phase of high-order harmonics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transverse Electromagnetic Mode Conversion for High-Harmonic Self-Probing Spectroscopy

We report on high-order harmonic (HHG) two-source interferometry (TSI) in molecular gases. We used a 0-π phase plate to create two bright spots at the focus of a lens by converting a Gaussian laser beam into a TEM01 Transverse Electromagnetic Mode. The two bright foci produce two synchronized HHG sources. One of them is used to probe on-going dynamics in the generating medium, while the other s...

متن کامل

Multichannel interferometry using high-order rotating diffraction gratings

We report the successful construction and operation of a far-infrared (337 pm) interferometer based on a multiple-order diffraction grating wheel. On reflection from the wheel circumference, the incident laser beam is diffracted into a number ( 12) of approximately equal intensity high-order beams. Since the Doppler offset of the beams is proportional to the diffraction order, information encod...

متن کامل

Ultra-high Sensitivity Accelerometers and Gyroscopes Using Neutral Atom Matter-wave Interferometry*

This paper shows that matter-wave interferometers employing low-velocity neutral atoms can be used as inertial sensors with sensitivities that exceed those of conventional mechanical sensors and multiple circuit optical interferometers by many powers of ten. The energy and mass dependence of the phase shifts that are due to rotation and acceleration are different. Thus a pair of interferometers...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Phase effects owing to multilayer coatings in a two-mirror extreme-ultraviolet schwarzschild objective.

The aberrations of a multilayer-coated reflective Schwarzschild objective, which are influenced both by mirror surface profiles and by multilayer coatings, are evaluated with a phase-shifting point diffraction interferometer operating in the extreme ultraviolet. Using wave-front measurements at multiple wavelengths near 13.4 nm, we observed chromatic aberrations and wavelength-dependent transmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2003