Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) - a practical application.

نویسندگان

  • Renata Brodzka
  • Małgorzata Trzcinka-Ochocka
  • Beata Janasik
چکیده

OBJECTIVES The method for the determination of As, Al, Cd, Ni, Pb (toxic elements) and Cr, Co, Cu, Fe, Mn, Zn (essential elements) in human urine by the use of Inductively Coupled Plasma Mass Spectrometry (quadrupole ICP-MS DRCe Elan, Perkin Elmer) with the dynamic reaction cell (DRC) was developed. MATERIALS AND METHODS The method has been applied for multi-element analysis of the urine of 16 non-exposed healthy volunteers and 27 workers employed in a copper smelter. The analysis was conducted after initial 10-fold dilution of the urine samples with 0,1% nitric acid. Rhodium was used as an internal standard. The method validation parameters such as detection limit, sensitivity, precision were described for all elements. Accuracy of the method was checked by the regular use of certified reference materials ClinCheck®-Control Urine (Recipe) as well as by participation of the laboratory in the German External Quality Assessment Scheme (G-EQUAS). RESULTS The detection limits (DL 3s) of the applied method were 0.025, 0.007, 0.002, 0.004, 0.004, 0.086, 0.037, 0.009, 0.016, 0.008, 0.064 (μg/l) for Al, As, Cd, Cr, Co, Cu, Fe, Mn, Ni, Pb, Zn in urine, respectively. For each element linearity with correlation coefficient of at least 0.999 was determined. Spectral interferences from some of the ions were removed using DRC-e with addition of alternative gas: methane for cobalt, copper, cadmium, chromium, iron, manganese, nickel and rhodium, and oxygen for arsenic. CONCLUSIONS The developed method allows to determine simultaneously eleven elements in the urine with low detection limits, high sensitivity and good accuracy. Moreover, the method is appropriate for the assessment of both environmental and occupational exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elan Drc Icp-ms System with Dynamic Bandpass Tuning

Introduction Inductively Coupled Plasma Mass Spectrometry (ICP-MS) typically provides detection limits in the low-ppt to sub-ppt range for all but a few of over 70 elements. Unfortunately, for a handful of elements, conventional ICP-MS cannot provide the best possible detection limits. The detection limits for these elements are limited by plasma or sample matrix-based polyatomic interferences....

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل

Oxygenation mechanism of ions in dynamic reaction cell ICP-MS.

A dynamic reaction cell (DRC) is one of the most effective tools for eliminating spectral interferences caused by polyatomic molecules in inductively coupled plasma mass spectrometry (ICP-MS). Oxygen gas (O2), by producing oxygenated ions, is very effective in reducing some specific spectral interferences. In this study, the oxygenation of elemental ions (M(+)) in the DRC was investigated exper...

متن کامل

Interference-free determination of Ca in ultrapure water, concentrated acids and hydrogen peroxide using isotope dilution, ICP-MS and CH3F as a reaction gas

An analytical method was developed for Ca determination in ultrapure water, concentrated acids and hydrogen peroxide by ICP-MS, using CH3F as reaction gas in the dynamic reaction cell (DRC) and isotopic dilution (ID) as strategy of calibration for improve the accuracy and allow interferencefree Ca determination.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of occupational medicine and environmental health

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2013