In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase. In addition to this, the NiO nanostructures were used in the development of a zinc ion sensor electrode by functionalization with the highly selective zinc ion ionophore 12-crown-4. The developed zinc ion sensor electrode has shown a good linear potentiometric response for a wide range of zinc ion concentrations, ranging from 0.001 mM to 100 mM, with sensitivity of 36 mV/decade. The detection limit of the present zinc ion sensor was found to be 0.0005 mM and it also displays a fast response time of less than 10 s. The proposed zinc ion sensor electrode has also shown good reproducibility, repeatability, storage stability and selectivity. The zinc ion sensor based on the functionalized NiO nanostructures was also used as indicator electrode in potentiometric titrations and it has demonstrated an acceptable stoichiometric relationship for the determination of zinc ion in unknown samples. The NiO nanostructures-based zinc ion sensor has potential for analysing zinc ion in various industrial, clinical and other real samples.
منابع مشابه
Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
متن کاملDetermination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design
The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...
متن کاملPotentiometric Based Membrane Sensor for Zinc Ion
A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08 10-5-1.00 10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...
متن کاملNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...