Comparison of photodiode nonlinearity measurement systems.
نویسندگان
چکیده
Photodiode nonlinearity measurements using one-, two- and three-tone measurement systems are compared with each other, to investigate the comparison accuracy between setups. The mathematical relationship between each setup is analyzed, and data on multiple devices are compared to find under which conditions the measurements are comparable. It is shown that the three measurement systems can be used interchangeably only when the distortion adheres to the expected mathematical slopes.
منابع مشابه
Large Signal Bias Dependent Modeling of Avalanche Photodiode Based on Pulsed RF Measurement
This work presents a method for large signal characterization of avalanche photodiode (APD) where measurements were carried out using pulsed RF signal at different DC bias points to extract dispersive parameters of the avalanche photodiode. Pulsed optical excitation on the photodiode were synchronized with the pulsed RF signal using a synchronization circuit and in this way characterization of ...
متن کاملComparison of the current of UV ray radiation on PIN Silicon photodiode and Gallium Arsenide
The high-energy UV ray radiation on PIN Silicon photodiodes reduces the optimal parameters of these photodiodes. In this paper, by representing a model, we compare the effect of UV dose on the bright current in these two types of photodiodes and confirm the analytic relationships in order to simulate a model with the help of the Silvaco- Atlas software. In this model, Silicon photodiodes and Ga...
متن کاملColumn-Parallel Single Slope ADC with Digital Correlated Multiple Sampling for Low Noise CMOS Image Sensors
This paper presents a low noise CMOS image sensor (CIS) using 10/12 bit configurable column-parallel single slope ADCs (SS-ADCs) and digital correlated multiple sampling (CMS). The sensor used is a conventional 4T active pixel with pinned-photodiode as detector. The test sensor has been fabricated in 0.18 μm CMOS image sensor process from TSMC. The ADC nonlinearity measurement result shows tota...
متن کاملModeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm
Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...
متن کاملExperimental Comparison of Four Different CMOS Pixel Architectures Used in Indirect Time-of-Flight Distance Measurement Sensors
Four different pixel architectures to be used in CMOS based indirect time-of-flight (ToF) rangers were designed, fabricated and characterised. The measured results are presented here for their direct comparison. Sharing a very similar, yet case optimised readout circuitry in each case, three fabricated CMOS rangers were based respectively on a pinned photodiode (PPD), a photogate, and a newly d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 13 شماره
صفحات -