Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis
نویسندگان
چکیده
PURPOSE The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. METHODS Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. RESULTS The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50 degrees-52 degrees ) and type II (mean 62.50 degrees-64 degrees ), with significant differences between them (p < 0.001). The angle between the major craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25 degrees while the angle with the upper posterior column of the scapula averaged 8 degrees . CONCLUSION Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.
منابع مشابه
Glenohumeral Anatomic Study. A Comparison of Male and Female Shoulders with Similar Average Age and BMI.
INTRODUCTION Numerous anatomic studies of the shoulder have quantified the size, shape, and variability of either the humerus or scapula individually. However, few have attempted to quantify the relationship of the humerus to the scapula to better understand the spatial variation of these bones in both male and female shoulders. METHODS Seventy-four cadaveric shoulder CT scans (37 males and 3...
متن کاملQuantitative 3-dimensional Computerized Tomography Modeling of Isolated Greater Tuberosity Fractures with and without Shoulder Dislocation
Background: The aim of this study was to assess differences in fracture morphology and displacement betweenisolated greater tuberosity (GT) fractures (i.e. fractures of the greater tuberosity without other fractures of the proximalhumerus) with and without shoulder dislocation utilizing quantitative 3-dimensional CT imaging.Methods: Thirty-four CT-scans of isolated greater tuberosity fractures ...
متن کاملThree-dimensional measurement method of arthritic glenoid cavity morphology: feasibility and reproducibility.
INTRODUCTION Glenoid component loosening is the main complication of total shoulder arthroplasty. Better knowledge of the arthritic glenoid cavity anatomy can help in developing new implants and techniques. The goal of this study was to describe and validate the reproducibility of a CT scan-based, 3D measurement method used to describe various parameters characterizing arthritic glenoid cavity ...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملThree-Dimensional Computed Tomography Diagnosis of Cranium Bifidum with Meningocele in a Lamb
Abstract Case Description- A three-day-old male Kordi lamb had a soft painless fluctuating mass on the mid-parietal region, with no clinical signs except difficulty in standing; was referred to the clinic. Clinical Findings- Clinical examination revealed a normal body temperature, a heart rate, a respiratory rate, and inability to stand without any congenital defects Three-dimensional comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Orthopaedic Surgery and Research
دوره 3 شماره
صفحات -
تاریخ انتشار 2008