Aluminum(III) porphyrins are examined as potential fluoride selective ionophores in polymeric membrane type ionselective electrodes. Membranes formulated with Al(III) tetraphenyl (TPP) or octaethyl (OEP) porphyrins are shown to exhibit enhanced potentiometric selectivity for fluoride over more lipophilic anions, including perchlorate and thiocyanate. However, such membrane electrodes display undesirable super-Nernstian behavior, with concomitant slow response and recovery times. By employing a sterically hindered Al(III) picket fence porphyrin (PFP) complex as the membrane active species, fully reversible and Nernstian response toward fluoride is achieved. This finding suggests that the super-Nernstian behavior observed with the nonpicket fence metalloporphyrins is due to the formation of aggregate porphyrin species (likely dimers) within the membrane phase. The steric hindrance of the PFP ligand structure eliminates such chemistry, thus leading to theoretical response slopes toward fluoride. Addition of lipophilic anionic sites into the organic membranes enhances response and selectivity, indicating that the Al(III) porphyrin ionophores function as charged carrier type ionophores. Optimized membranes formulated with Al(III)PFP in an o-nitrophenyloctyl ether plasticized PVC film exhibit fast response to fluoride down to 40 mM, with very high selectivity over SCN , ClO4 , Cl , Br and NO3 (k< 10 3 for all anions tested). With further refinements in the membrane chemistry, it is anticipated that Al(III) porphyrin-based membrane electrodes can exhibit potentiometric fluoride response and selectivity that approaches that of the classical solid-state LaF3 crystal-based fluoride sensor.
منابع مشابه
Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity.
The role of lipophilic anionic and cationic additives on the potentiometric anion selectivities of polymer membrane electrodes prepared with various metalloporphyrins as anion selective ionophores is examined. The presence of lipophilic anionic sites (e.g. tetraphenylborate derivatives) is shown to enhance the non-Hofmeister anion selectivities of membranes doped with In(III) and Sn(IV) porphyr...
متن کاملPotassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کاملBinding studies and anion-selective electrodes with neutral isophthalamide-based receptors.
Two acyclic isophthalamide-based hosts have been synthesised and their anion binding properties have been evaluated by (1)H-NMR titrations. Different binding modes have been detected for the series of tested anions. The attachment of aminomethylpyrrole groups resulted in an improved binding selectivity. Additionally, the receptors have been incorporated as ionophores in plasticised polymeric me...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملChloride-selective membrane electrodes and optodes based on an indium(III) porphyrin for the determination of chloride in a sequential injection analysis system.
Two quasi-independent methods for potentiometric and optical determination of chloride were simultaneously implemented in a flow system, providing real-time assessment of the quality of results. A potentiometric and an optical polymeric membrane doped with the same indium(III) octaethyl-porphyrin were used as sensor ionophore. The working mechanism and the analytical characteristics of these po...