Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.
نویسندگان
چکیده
BACKGROUND The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuation at the start of inhalation. However, these recommendations were based on clinical studies using CFC (chlorofluorocarbon)-MDIs and in vitro studies of HFA (hydrofluoroalkane)-MDIs using idealized MDI techniques of uniform inhalation and actuation, disregarding the nonuniform techniques of actual patients. METHODS To better understand the effects of time-varying MDI usage parameters on lung deposition of aerosol delivered by an HFA-MDI, we conducted an in vitro study modeled on real-life variable inspiratory flow and actuation techniques recorded from 15 subjects with asthma/chronic obstructive pulmonary disease (COPD). We developed a model representing the time-varying inspiratory flow waveforms and actuation timings based on 43 MDI techniques recorded from patients. Furthermore, we constructed an in vitro experimental setup using a mouth-throat cast, programmable MDI actuator, and breath simulator to evaluate lung deposition for the MDI techniques derived from our model. RESULTS High inspiratory flow rates, 60-90 L/min, consistently resulted in high in vitro lung deposition (>40%) of aerosol (albuterol delivered from Ventolin HFA-MDI) compared to 30 L/min when MDI actuation occurred in the first half of inhalation. Also, positive coordination resulted in higher in vitro lung deposition compared with negative or zero coordination (actuating before or at the start of inspiration). Furthermore, variation in coordination affected lung deposition more significantly (23%) than flow rate or duration of inspiration (≤5%). CONCLUSIONS In an in vitro experimental model based on inhalation data from patients with asthma and COPD, we demonstrated that aerosol lung deposition emitted from Ventolin HFA-MDI is most optimal for MDI actuation in the first half of inspiration at high flow rates (60-90 L/min).
منابع مشابه
Demonstration of in vivo bioequivalence of a generic albuterol metered-dose inhaler to Ventolin.
STUDY OBJECTIVE To use histamine bronchoprovocation and bioassay statistical procedures to evaluate the in vivo bioequivalence of a generic albuterol metered-dose inhaler (MDI). DESIGN A randomized, double-blind, balanced, crossover design was used to determine the potency of each generic albuterol MDI actuation relative to Ventolin (Glaxo Wellcome; Research Triangle Park, NC) administration....
متن کاملAerosol deposition in the human lung following administration from a microprocessor controlled pressurised metered dose inhaler.
BACKGROUND Gamma scintigraphy was employed to assess the deposition of aerosols emitted from a pressurised metered dose inhaler (MDI) contained in a microprocessor controlled device (SmartMist), a system which analyses an inspiratory flow profile and automatically actuates the MDI when predefined conditions of flow rate and cumulative inspired volume coincide. METHODS Micronised salbutamol pa...
متن کاملCharacteristics influencing the effective administration of drugs as inhalation aerosols.
S tudies of the effective delivery of pharmaceutical inhalation aerosols have hinged on their particlesize characteristics and the mass, or dose, of drug delivered to the lung. Preparation and delivery of aerosols have been approached using these criteria with the intention of optimizing lung deposition. Aerosol particles and droplets exhibit a range of sizes which constitute their distribution...
متن کاملDosing efficiency and particle-size characteristics of pressurized metered-dose inhaler aerosols in narrow catheters.
An experimental in vitro model was used to determine the effects of intraluminal catheter diameter and length on the delivered dose and particle-size characteristics of salbutamol (albuterol) aerosol delivered by metered dose inhaler (MDI) (Ventolin, 100 micrograms per puff). The dose of aerosolized drug that exited a 16-cm-long tracheal tube with an inner diameter (ID) of 6 mm was compared wit...
متن کاملIn vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices.
Metered-dose inhalers (MDIs) are currently being reformulated to contain hydrofluoroalkanes (HFAs), which do not damage the Earth's ozone layer. As different formulations of inhaled drugs may behave differently when used with spacer devices, we wished to determine the amount of salbutamol available for inhalation from a conventional metered-dose inhaler (Ventolin) and a new HFA-containing formu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of aerosol medicine and pulmonary drug delivery
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2017