Radiation testing of the AeroForm co2-based breast tissue expander implant

نویسندگان

  • James L Rembert
  • Roxana Heitz
  • Adam Hoffman
چکیده

BACKGROUND Tissue expanders are used in breast reconstruction after mastectomy to stretch the remaining tissue to create space for placement of permanent breast implants. The AeroForm™ Tissue Expander, developed by AirXpanders™ Inc., contains electronic components designed to activate the release of carbon dioxide from an internal reservoir to inflate the expander. Breast cancer patients who undergo mastectomy and tissue expander/implant-based breast reconstruction may require radiation therapy at doses up to 50-60 Gy while the expander is in place. The ionizing radiation used in postmastectomy radiation therapy interacts with electronic components in medical implants, which may cause degradation in performance above certain levels. Most commercial electronic components used in medical devices, such as complementary metal-oxide semiconductor or bipolar integrated circuits can withstand radiation levels in the 50 Gy range without any performance degradation. Beyond this level, the performance may still be sufficient to guarantee functionality, but this needs to be confirmed at the system and electronic circuit level. We assessed the impact of radiation levels up to 75 Gy on 32 AeroForm™ Tissue Expanders (AirXpanders, Inc., Palo Alto, CA USA) and on the associated internal printed circuit assemblies. FINDINGS The electronics inside the AeroForm™ Tissue Expander implant continued to function properly after exposure to radiation levels up to 75 Gy, which is well above the maximum total dose level typically used in postmastectomy radiation therapy. CONCLUSIONS Standard postmastectomy radiation therapy doses do not damage or affect the functionality of the AeroForm™ Tissue Expander.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate Breast Tissue Expander-Implant Reconstruction With Inferolateral AlloDerm Hammock and Postoperative Radiation: A Preliminary Report

OBJECTIVE To preserve the mastectomy skin envelope in select patients destined to receive radiation following mastectomy, we performed immediate tissue expander-implant reconstruction with a subpectoral tissue expander and an inferolateral AlloDerm hammock for complete implant coverage. We hypothesized that the AlloDerm hammock may allow greater intraoperative volume expansion and potentially a...

متن کامل

Abstract: Evaluation of a New Concept in Two-Stage Breast Reconstruction: Patient Controlled Tissue Expansion using the AeroForm CO2 Tissue Expander System

ConClusion: We present a validated risk stratification tool for predicting 30-day SSM following reduction mammoplasty using data that are readily available to the clinician. This may allow targeted screening and intervention in high-risk patients, better counseling, selective resident participation, and ultimately decrease overall health-care costs. This is the first study to date that provides...

متن کامل

Outcomes of immediate tissue expander breast reconstruction followed by reconstruction of choice in the setting of postmastectomy radiation therapy: reply.

A common sequence for performing staged tissue expander breast reconstruction is to immediately insert a tissue expander, complete expansion before radiotherapy, and then perform the definitive reconstruction after radiotherapy is complete. This study evaluates the outcomes of this treatment regimen in 237 patients over a 10-year period at Northwestern Memorial Hospital. Overall, 62% of the pat...

متن کامل

Tissue Expander versus Tissue Expander and Latissimus Flap in Morbidly Obese Breast Reconstruction Patients

BACKGROUND Immediate postmastectomy breast reconstruction in morbidly obese patients represents a challenge because neither prosthetic nor abdominal-based options may be suitable. METHODS This study compared a previously published cohort of immediate prosthetic reconstruction of 346 patients (511 breasts) of whom 49 patients (67 breasts) were morbidly obese (defined as a body mass index > 35)...

متن کامل

The Timing of Implant Exchange in the Development of Capsular Contracture After Breast Reconstruction

OBJECTIVE Capsular contracture is a common complication associated with reconstructive breast surgery. The optimal time interval between the completion of tissue expansion and placement of the permanent implant is arbitrary and incompletely studied in the literature. The aim of the study was to determine whether the time interval between completion of expansion and placement of the permanent im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013