Self-Test Procedures for Gas Sensors Embedded in Microreactor Systems
نویسندگان
چکیده
Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the help of an external micro-pump, such systems can be operated in a periodic manner alternating between flow and no-flow conditions, thus allowing repetitive measurements of the sensor resistances under clean air, R 0 , and under gas exposure, R g a s , to be obtained, even under field conditions. With these pairs of resistance values, eventual drifts in the sensor baseline resistance can be detected and drift-corrected values of the relative resistance response R e s p = ( R 0 - R g a s ) / R 0 can be determined. Residual poisoning-induced changes in the relative resistance response can be detected by reference to humidity measurements taken with room-temperature-operated capacitive humidity sensors which are insensitive to the poisoning processes operative on heated MOX gas sensors.
منابع مشابه
Thickness Dependence of Sensitivity in Thin Film Tin Oxide Gas Sensors Deposited by Vapor Pyrolysis
Transparent SnO2 thin films were deposited on porcelain substrates using a chemical vapor deposition technique based on the hydrolysis of SnCl4 at elevated temperatures. A reduced pressure self-contained evaporation chamber was designed for the process where the pyrolysis of SnCl4 at the presence of water vapor was carried out. Resistive gas sensors were fabricated by providing ohmic contacts o...
متن کاملEmbedded Memory Test Strategies and Repair
The demand of self-testing proportionally increases with memory size in System on Chip (SoC). SoC architecture normally occupies the majority of its area by memories. Due to increase in density of embedded memories, there is a need of self-testing mechanism in SoC design. Therefore, this research study focuses on this problem and introduces a smooth solution for self-testing. In the proposed m...
متن کاملCouple Stress Effect on Micro/Nanocantilever-based Capacitive Gas Sensor
Micro/nanocantilevers have been employed as sensors in many applications including chemical and biosensing. Due to their high sensitivity and potential for scalability, miniature sensing systems are in wide use and will likely become more prevalent in micro/nano-electromechanical systems (M-NEMSs). This paper is mainly focused on the use of sensing systems that employ micro/nano-size cantilever...
متن کاملCentrifugation assisted microreactor enables facile integration of trypsin digestion, hydrophilic interaction chromatography enrichment, and on-column deglycosylation for rapid and sensitive N-glycoproteome analysis.
Sample handling procedures including protein digestion, glycopeptide enrichment, and deglycosylation have significant impact on the performance of glycoproteome analysis. Several glycoproteomic analysis systems were developed to integrate some of these sample preparation procedures. However, no microsystem integrates all of above three procedures together. In this work, we developed a glycoprot...
متن کاملA CFD Simulation of Hydrogen Production in Microreactors
In this study, the modeling of hydrogen production process in microreactors by methanol-steam reforming reaction is investigated. The catalytic reaction of methanol-steam reforming producing hydrogen is simulated considering a 3D geometry for the microreactor. To calculate diffusion among species, mixture average correlations are compared to Stephan-Maxwell equations. The reactions occurring in...
متن کامل