Simultaneous absolute quantification of target and control templates by real-time fluorescence reverse transcription-PCR using 4-(4'-dimethylaminophenylazo)benzoic acid as a dark quencher dye.
نویسندگان
چکیده
BACKGROUND Despite the many advantages of real-time fluorescence reverse transcription-PCR (RT-PCR) as a quantitative analytical tool, simultaneous quantification of target and reference templates within one reaction has not been reported. We developed such an assay with an internal reference template. METHODS For quantification of target and reference sequences, we used two fluorescent probes in one reaction vessel on an ABI PRISM 7700 SDS instrument. Fluorescent probes were labeled with either 6-carboxy-fluorescein or hexachloro-6-carboxy-fluorescein as reporter dye and 4-(4'-dimethylaminophenylazo)benzoic acid (DABCYL) as a dark quencher fluorophore. To test the sensitivity and specificity of this assay, serial dilutions of reference and target templates were analyzed in one PCR reaction. In the presence of 10 beta-actin molecules as control templates, 10(5) bcr/abl molecules were amplified, and 10(5) beta-actin molecules were amplified in the presence of 10 bcr/abl copies. We also performed single and duplex measurements on samples from five patients with documented Philadelphia chromosome-positive chronic myelogenous leukemia disease courses (72 samples) and three with minor bcr/abl+ acute myelogenous leukemias (26 samples). RESULTS For M-bcr/abl duplex RT-PCR, the correlation coefficient (r) for starting template amounts and threshold cycle values was 0.99; for m-bcr/abl, r = 0.96, indicating a precise log-linear relation for 10-10(5) copies/100 ng of cDNA. In the same PCR reactions, r = 0.99 for beta-actin (coamplified with M-bcr/abl or m-bcr/abl) for 10(3)-10(7) copies/100 ng cDNA. The linear correlation coefficient for single and duplex measurements was 0.98 for M- and m-bcr/abl in patient samples. CONCLUSIONS DABCYL can be used as dark quencher fluorophore in real-time fluorescence PCR. The duplex fluorescence RT-PCR assay for bcr/abl and beta-actin transcripts allows monitoring of bcr/abl+ leukemias.
منابع مشابه
Synthesis and evaluation of a photoresponsive quencher for fluorescent hybridization probes.
Nowadays, most nucleic acid detections using fluorescent probes rely on quenching of fluorescence by energy transfer from one fluorophore to another or to a non-fluorescent molecule (quencher). The most widely used quencher in fluorescent probes is 4-((4-(dimethylamino)phenyl)azo)benzoic acid (DABCYL). We targeted a nucleoside-DABCYL analogue which could be incorporated anywhere in an oligonucl...
متن کاملAbsolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR
The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...
متن کاملDetection of Listeria monocytogenes from a model food by fluorescence resonance energy transfer-based PCR with an asymmetric fluorogenic probe set.
It has been shown that fluorescence resonance energy transfer (FRET)-based PCR, including the TaqMan assay and molecular beacons, has potential for rapid detection of pathogens. In these promising real-time detection assays a single internal oligonucleotide probe labeled on both the 5' (reporter) and 3' (quencher) ends is used for selective generation of fluorescence. In this paper, we describe...
متن کاملA closed tube format for amplification and detection of DNA based on energy transfer.
A new method for the direct detection of PCR-amplified DNA in a closed system is described. The method is based on the incorporation of energy transfer-labeled primers into the amplification product. The PCR primers contain hairpin structures on their 5'ends with donor and acceptor moieties located in close proximity on the hairpin stem. The primers are designed in such a way that a fluorescent...
متن کاملModulation of intramolecular heterodimer-induced fluorescence quenching of tricarbocyanine dye for the development of fluorescent sensor.
Various approaches have been used to modulate the fluorescence changes of sensors in the presence of target analytes, including intramolecular interaction between fluorophores or between fluorophore and other molecular species, like resonance energy transfer (RET). Here, we focus on fluorescence quenching by intramolecular heterodimer complex formation, which can be modulated over a shorter dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2001