Measuring higher order optical aberrations of the human eye: techniques and applications.

نویسندگان

  • L Alberto V Carvalho
  • J C Castro
  • L Antonio V Carvalho
چکیده

In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia) and higher order aberrations (coma, spherical aberration, etc.). We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45 degrees and 90 degrees. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE) of less than 0.1 micro m for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5 degrees for the axis. This precision is sufficient for customized corneal ablations, among other applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Surgery Feature Story

SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 35 T he introduction of wavefront-sensing techniques to ophthalmology has redefined the clinical meaning of refractive error. Now, all imperfections in the components and materials within the eye that cause light rays to deviate from their desired path are referred to as optical aberrations. Lower-order aberrations (defocus and astigmati...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Micrometric Control of the Optics of the Human Eye: Environment or Genes?

Purpose The human eye has typically more optical aberrations than conventional artificial optical systems. While the lower order modes (defocus and astigmatism) are well studied, our purpose is to explore the influence of genes versus the environment on the higher order aberrations of the optical components of the eye. Methods We have performed a classical twin study in a sample from the Regi...

متن کامل

Generation of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation

Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...

متن کامل

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 2002