Differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation according to the severity and characteristics.

نویسندگان

  • Jaehuk Choi
  • Ran Heo
  • Geu-Ru Hong
  • Hyuk-Jae Chang
  • Ji Min Sung
  • Sang Hoon Shin
  • In Jeong Cho
  • Chi-Young Shim
  • Namsik Chung
چکیده

BACKGROUND The aim of this study is to explore the differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation (MR). Two-dimensional color Doppler echocardiography-based MR quantification has well-documented limitations. METHODS AND RESULTS We consecutively enrolled 221 patients with MR. Adequate image quality was obtained by 2D- and 3D-color Doppler echocardiography in 211 (95.5%) patients. The quantitative differences between the MR volumes obtained by 2D- and 3D-proximal isovelocity surface area (PISA) were analyzed in various MR subgroups. In the validation cohort (n=52), MR volume obtained by 3D-PISA showed a better agreement with phase-contrast cardiac MRI than 2D-PISA (r=0.97 versus 0.84). In all 211 patients, 2D-PISA underestimated the MR volume when compared with 3D-PISA (52.4±19.6 versus 59.5±25.6 mL; P=0.005). A total of 33.3% with severe MR based on 3D-PISA were incorrectly assessed by 2D-PISA as having nonsevere MR. In the subgroup analysis, the MR severity (odds ratio, 6.96; 95% confidence interval, 3.04-15.94; P<0.001) and having an asymmetrical orifice (odds ratio, 11.48; 95% confidence interval, 3.72-35.4; P<0.001), and an eccentric jet (odds ratio, 3.82; 95% confidence interval, 1.27-11.48; P=0.017) were predictors of significant difference in MR volume (>15 mL) between 2D- and 3D-PISA methods. CONCLUSIONS Quantification of MR by 3D-PISA method is clinically feasible and more accurate than the current 2D-PISA method. MR quantification by 2D-PISA significantly underestimated MR volume with severe, eccentric MR with an asymmetrical orifice. This article demonstrates that 3D-color Doppler echocardiography could be used as a valuable tool to confirm treatment strategy in patients with significant MR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Three-Dimensional Echocardiographic Assessment of Severity of Mitral Regurgitation Using Proximal Isovelocity Surface Area and Vena Contracta Area Method. Lessons We Learned and Clinical Implications

Mitral regurgitation (MR) is considered the most common valve disease with a prevalence of 2-3 % of significant regurgitation (moderate to severe and severe) in the general population. Accurate assessment of the severity of regurgitation was demonstrated to be of significant importance for patient management and prognosis and consequently has been widely recognized in recent guidelines. However...

متن کامل

Determination of regurgitant fraction in isolated mitral or aortic regurgitation by pulsed Doppler two-dimensional echocardiography.

Measurements of mitral and aortic valve flows were obtained with two-dimensional Doppler echocardiography in 25 patients with isolated mitral (n = 19) or aortic (n = 6) regurgitation and regurgitant fraction was calculated as the difference between the two flows divided by the flow through the regurgitant valve. Results were compared with measurements of regurgitant fraction determined by combi...

متن کامل

Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.

BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 7 3  شماره 

صفحات  -