Pulse wave analysis permits non-invasive assessment of arterial elasticity indices. The contour varies in different parts of the circulation. It depends on physiological or pathophysiological conditions of the organism. The pathological events like arteriosclerosis or diabetes have a primary effect to the artery elasticity. Hypertension or some heart diseases also influence the pulse wave velocity and resulted in earlier wave reflections. There are several methods of pulse wave measurements based on different principles and depending on the type of measured pulse wave. The evaluation parameters can be assessed from the time domain, derivations, velocity or frequency domain. The main aim of this review article is to offer a recent overview of pulse wave measurement parameters and main results obtained. The principles of pulse wave measurement and current experience in clinical practice are shortly discussed too.
منابع مشابه
EXPERIMENTAL EVALUATION OF BLAST WAVE PARAMETERS IN UNDERWATER EXPLOSION OF HEXOGEN CHARGES
Behavior of blast wave in underwater explosion is of interest to metal forming community and ship designers. Underwater detonation is, also a potential hazard to the water intakes or a plant spent fuel pool. In this paper, some techniques for calculating free-field blast parameters such as pressure and impulse in underwater explosion and prediction of bubble pulsation parameters are presented a...
متن کاملSmooth muscle relaxation: effects on arterial compliance, distensibility, elastic modulus, and pulse wave velocity.
Compliance, distensibility, incremental elastic modulus (E(inc)), and pulse wave velocity are all terms used to describe the mechanical properties of arteries. Previous studies assessing the effects of smooth muscle relaxation on each of these parameters have produced conflicting results. Our laboratory has previously demonstrated that intrabrachial infusion of nitroglycerin in normal human sub...
متن کاملEffects on Arterial Compliance, Distensibility, Elastic Modulus, and Pulse Wave Velocity
Compliance, distensibility, incremental elastic modulus (Einc), and pulse wave velocity are all terms used to describe the mechanical properties of arteries. Previous studies assessing the effects of smooth muscle relaxation on each of these parameters have produced conflicting results. Our laboratory has previously demonstrated that intrabrachial infusion of nitroglycerin in normal human subje...
متن کاملWave breaking in the short-pulse equation
Sufficient conditions for wave breaking are found for the short-pulse equation describing wave packets of few cycles on the ultra-short pulse scale. The analysis relies on the method of characteristics and conserved quantities of the short-pulse equation and holds both on an infinite line and in a periodic domain. Numerical illustrations of the finite-time wave breaking are given in a periodic ...
متن کاملDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological research
دوره 58 4 شماره
صفحات -
تاریخ انتشار 2009