Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation.

نویسندگان

  • Antonio Colombo
  • Dejan Orlic
  • Goran Stankovic
  • Nicola Corvaja
  • Vassilis Spanos
  • Matteo Montorfano
  • Francesco Liistro
  • Mauro Carlino
  • Flavio Airoldi
  • Alaide Chieffo
  • Carlo Di Mario
چکیده

BACKGROUND Restenosis after implantation of drug-eluting stents (DES) is a rare phenomenon, occurring more frequently peri-stent. METHODS AND RESULTS We evaluated the pattern of restenosis occurring after implantation of DES in unselected lesions. From April 15 to December 6, 2002, we treated 368 patients with 735 lesions by using 841 rapamycin-eluting stents (Cypher, Cordis, a Johnson & Johnson Company). Mean baseline lesion length was 17.48+/-12.19 mm, and mean stent length was 27.59+/-14.02 mm. Follow-up ischemia-driven angiography was performed in 24 patients. Eleven patients had angiographic restenosis (> or =50% diameter stenosis) in 14 stented segments (stent and 5 mm proximal and distal to the stent). The pattern of restenosis in all 14 stented segments was focal, and in 6 of them it was multifocal, occurring inside the stents. Mean length of restenotic lesions was 5.62+/-1.90 mm, with a range from 2.54 to 8.44 mm. One multifocal restenosis involved also the distal stent margin. Intravascular ultrasound evaluation at follow-up, performed in 2 patients, showed significant lumen obstruction attributable to in-stent hyperplasia in both cases. Individual cases can be viewed in the Data Supplement. CONCLUSIONS The pattern of restenotic lesions after rapamycin-eluting stent implantation was focal and mostly inside the stent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine sirolimus eluting stent implantation for unselected in-stent restenosis: insights from the rapamycin eluting stent evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry.

OBJECTIVE To assess the effectiveness of routine sirolimus eluting stent (SES) implantation for unselected patients with in-stent restenosis and to provide preliminary information about the angiographic outcome for lesion subgroups and for different in-stent restenosis patterns. DESIGN Prospective, single centre registry. SETTING Tertiary referral centre. PATIENTS 44 consecutive patients ...

متن کامل

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.

AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...

متن کامل

Angiographic patterns of restenosis after sirolimus-eluting stent implantation.

BACKGROUND Large-scale randomized trials demonstrate a high proportion of focal restenosis after drug-eluting stent (DES) implantation. On the other hand, recent reports have shown that in real-world practice a significant proportion of the restenosis is non-focal when DESs are used in unselected lesions. The present study evaluated angiographic patterns of restenosis after sirolimus-eluting st...

متن کامل

Angiographic patterns of restenosis with 2nd generation drug-eluting stent: comparative analysis from a 10-year single-center experience .

The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared ...

متن کامل

Randomized trial of a nonpolymer-based rapamycin-eluting stent versus a polymer-based paclitaxel-eluting stent for the reduction of late lumen loss.

BACKGROUND Although drug-eluting stents (DESs) constitute a major achievement in preventing restenosis, concerns remain regarding the increased inflammatory and thrombogenic responses associated with the polymers used. Recently, we showed that a nonpolymer on-site coating with rapamycin not only is feasible and safe but also leads to a dose-dependent reduction in restenosis. METHODS AND RESUL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 107 17  شماره 

صفحات  -

تاریخ انتشار 2003