Radiofrequency puncture of the fossa ovalis for resistant transseptal access.
نویسندگان
چکیده
BACKGROUND Transseptal puncture with a conventional mechanical technique can fail because of a resistant interatrial septum. We evaluated the efficacy and safety of a new method to cross-resistant septae by transmitting radiofrequency (RF) energy through the transseptal needle. METHODS AND RESULTS Among 269 consecutive transseptal punctures, 13 (5%) were unsuccessful in 12 different patients (11 men aged 52+/-12 years) using the conventional Brockenbrough technique. All 12 patients had previously undergone at least 1 transseptal catheterization. The needle position in relation to the fossa ovalis was assessed by fluoroscopy in orthogonal views and was confirmed with contrast injection and by visualizing the characteristic "tenting" of the fossa ovalis. Before using RF energy, there were a median of 6 unsuccessful attempts to perforate the septum conventionally, with 1 pericardial puncture (with a nonsignificant effusion). RF transseptal puncture was then performed by delivering unipolar RF with manual contact between the ablation catheter and the proximal extremity of the needle at the patient's groin. RF transseptal puncture was achieved at the first attempt in all patients within a median of 1 second (interquartile range, 1 to 4) and without any complication. The only parameter predictive of a septum resistant to conventional puncture was the total number of transseptal catheterizations (3.2+/-1 versus 1.8+/-1, P<0.001). CONCLUSIONS Transmission of RF energy from the ablation catheter up to the tip of the transseptal needle provides an easy and safe method for piercing the fossa ovalis when the conventional approach fails because of a resistant septum.
منابع مشابه
Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: intracardiac echocardiography-guided transseptal left heart catheterization.
Intracardiac echocardiography (ICE) serves as an adjunct to fluoroscopy for electrophysiological procedures by identifying critical anatomic landmarks and confirming catheter-endocardial contact. In the present study, we investigated the usefulness of ICE for radiofrequency catheter ablation. ICE was utilized to guide transseptal puncture in 19 patients undergoing radiofrequency catheter ablati...
متن کاملIncidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.
BACKGROUND The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. METHODS AND RESULTS A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP wit...
متن کاملTransseptal left heart catheterisation guided by intracardiac echocardiography.
OBJECTIVE To develop a novel approach of transseptal puncture guided by intracardiac echocardiography and to assess its efficacy. METHODS Transcatheter intracardiac echocardiography with a 9 MHz rotating transducer was performed to guide transseptal puncture in 12 patients (mean age 43.1 years, range 31-68) who underwent radiofrequency catheter ablation of left sided accessory pathways. Initi...
متن کامل[Learning process for transseptal puncture guided by intracardiac echocardiography].
We prospectively analyzed the learning process for transseptal catheterization guided by intracardiac echocardiography, in 50 patients who underwent radiofrequency ablation for left atrial arrhythmias. In 20 patients the intracardiac echocardiography catheter was positioned in the right atrium to visualize the fossa ovalis and the tenting of the fossa caused by the Brockenbrough needle. In the ...
متن کاملNRG™ RF powered transseptal needle: a useful technique for transcatheter atrial septostomy and Fontan fenestration: report of three cases.
Transseptal puncture (TSP) is a frequently performed procedure for gaining access to the left atrium for catheter ablation, hemodynamic assessment of the left heart, left ventricular assist device implantation, percutaneous left atrial appendage closure or mitral valvuloplasty during childhood and adulthood. The standard technique for transseptal puncture applies mechanical pressure on the foss...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 1 3 شماره
صفحات -
تاریخ انتشار 2008