Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology.
نویسندگان
چکیده
The fabrication of microelectrodes integrated within ultra-low-volume microtiter chambers for the amperometric determination of metabolites continues to be of interest in the subject of single-cell and high-throughput screening. The microsystem described in this paper consists of a two-microelectrode sensor with a microfluidic dispensation technology, which is able to deliver both very low titers (6.5 pL) and single heart cells into a low-volume microphotoelectrochemical cell. Devices were fabricated using photolithography and liftoff giving reproducible sensors integrated within high aspect ratio titer chambers (with a volume of 360 pL), made of the photoepoxy SU8. In this paper, the determination of lactate was optimized using an enzyme-linked assay based upon lactate oxidase, involving the amperometric determination of hydrogen peroxide at +640 mV versus an internal Ag/AgCl pseudoreference. The microsystem (including the microfluidic dispensers and structures as well as the microsensor) was subsequently used to measure the lactate content of single heart cells. Dynamic electrochemical measurements of lactate during cell permeabilization are presented. We also show the use of respiratory uncouplers to simulate ischemia in the single myocyte and show that, as expected, the rate of lactate production from the hypoxic heart cell is greater than that within the normoxic healthy myocyte.
منابع مشابه
A Novel Very High Performance CMOS Current Mirror with extremely low input and ultra high output resistance
In this paper a novel very high performance current mirror is presented. It favorably benefits from such excellent parameters as: Ultra high output resistance (36.9GΩ), extremely low input resistance (0.0058Ω), low output (~0.18V) and low input voltage (~0.18V) operation, very low power consumption (20μW), very low offset current (1pA), ultra wide current dynamic range (150dB), and ultra high a...
متن کاملMulti-Area State Estimation Based on PMU Measurements in Distribution Networks
State estimation in the energy management center of active distribution networks has attracted many attentions. Considering an increase in complexity and real-time management of active distribution networks and knowing the network information at each time instant are necessary. This article presents a two-step multi-area state estimation method in balanced active distribution networks. The prop...
متن کاملLow-cost Vector Network Analyzer for Biomedical Applications
A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...
متن کاملInfluence of Thickness and Number of Silver Layers in the Electrical and Optical Properties of ZnO/Ag/ZnO/Ag/ZnO ultra-Thin Films Deposited on the Glass for Low-Emissivity Applications
We report on transparent ZnO/Ag/ZnO and ZnO/Ag/ZnO/Ag/ZnO thin-films were deposited on the glass substrate by RF and DC sputtering for ZnO and Ag targets, respectively. The electrical and optical properties of the single and double Low Emissivity coatings were investigated with respect to the deposition time of Ag mid layer. The visible transmittance remains about 65% for single and 45% for...
متن کاملImprovement in Differential GPS Accuracy using Kalman Filter
Global Positioning System (GPS) is proven to be an accurate positioning sensor. However, there are several sources of errors such as ionosphere and troposphere effects, satellite time errors, errors of orbit data, receivers errors, and errors resulting from multi-path effect which reduce the accuracy of low-cost GPS receivers. These sources of errors also limit the use of single-frequency GPS r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 74 4 شماره
صفحات -
تاریخ انتشار 2002