Peptide and protein quantification using iTRAQ with electron transfer dissociation.

نویسندگان

  • Doug Phanstiel
  • Yi Zhang
  • Jarrod A Marto
  • Joshua J Coon
چکیده

Electron transfer dissociation (ETD) has become increasingly used in proteomic analyses due to its complementarity to collision-activated dissociation (CAD) and its ability to sequence peptides with post-translation modifications (PTMs). It was previously unknown, however, whether ETD would be compatible with a commonly employed quantification technique, isobaric tags for relative and absolute quantification (iTRAQ), since the fragmentation mechanisms and pathways of ETD differ significantly from CAD. We demonstrate here that ETD of iTRAQ labeled peptides produces c- and z-type fragment ions as well as reporter ions that are unique from those produced by CAD. Exact molecular formulas of product ions were determined by ETD fragmentation of iTRAQ-labeled synthetic peptides followed by high mass accuracy orbitrap mass analysis. These experiments revealed that ETD cleavage of the N-C(alpha) bond of the iTRAQ tag results in fragment ions that could be used for quantification. Synthetic peptide work demonstrates that these fragment ions provide up to three channels of quantification and that the quality is similar to that provided by beam-type CAD. Protein standards were used to evaluate peptide and protein quantification of iTRAQ labeling in conjunction with ETD, beam-type CAD, and pulsed Q dissociation (PQD) on a hybrid ion trap-orbitrap mass spectrometer. For reporter ion intensities above a certain threshold all three strategies provided reliable peptide quantification (average error <10%). Approximately 36%, 8%, and 16% of scans identified fall below this threshold for ETD, HCD, and PQD, respectively. At the protein level, average errors were 2.3%, 1.7%, and 3.6% for ETD, HCD, and PQD, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peptide quantification using 8-plex isobaric tags and electron transfer dissociation tandem mass spectrometry.

Isobaric tags for absolute and relative quantitation (iTRAQ) allow for simultaneous relative quantification of peptides from up to eight different samples. Typically peptides labeled with 8-plex iTRAQ tags are pooled and fragmented using beam-type collision activated dissociation (CAD) which, in addition to cleaving the peptide backbone bonds, cleaves the tag to produce reporter ions. The relat...

متن کامل

High precision quantitative proteomics using iTRAQ on an LTQ Orbitrap: a new mass spectrometric method combining the benefits of all.

The development of quantitative techniques in mass spectrometry has generated the ability to systematically monitor protein expression. Isobaric tags for relative and absolute quantification (iTRAQ) have become a widely used tool for the quantification of proteins. However, application of iTRAQ methodology using ion traps and hybrid mass spectrometers containing an ion trap such as the LTQ-Orbi...

متن کامل

Peptide Labeling with Isobaric Tags Yields Higher Identification Rates Using iTRAQ 4-Plex Compared to TMT 6-Plex and iTRAQ 8-Plex on LTQ Orbitrap

Peptide labeling with isobaric tags has become a popular technique in quantitative shotgun proteomics. Using two different samples viz. a protein mixture and HeLa extracts, we show that three commercially available isobaric tags differ with regard to peptide identification rates: The number of identified proteins and peptides was largest with iTRAQ 4-plex, followed by TMT 6-plex, and smallest w...

متن کامل

Census 2: isobaric labeling data analysis

MOTIVATION We introduce Census 2, an update of a mass spectrometry data analysis tool for peptide/protein quantification. New features for analysis of isobaric labeling, such as Tandem Mass Tag (TMT) or Isobaric Tags for Relative and Absolute Quantification (iTRAQ), have been added in this version, including a reporter ion impurity correction, a reporter ion intensity threshold filter and an op...

متن کامل

Analysis of the trypanosome flagellar proteome using a combined electron transfer/collisionally activated dissociation strategy.

The use of electron-transfer dissociation as an alternative peptide ion activation method for generation of protein sequence information is examined here in comparison with the conventional method of choice, collisionally activated dissociation, using a linear ion trapping instrument. Direct comparability between collisionally and electron-transfer-activated product ion data were ensured by emp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 19 9  شماره 

صفحات  -

تاریخ انتشار 2008